NO.
|
Item
|
Fault
|
Fail
Safe
|
1
|
In-car Sensor
|
Open or Short
|
Control with the value of
25°C(77.0°F)
|
2
|
Ambient temperature sensor
|
Open or Short
|
Control with the value of
20°C(67°F)
|
3
|
Evaporator temperature sensor
|
Open or Short
|
Control with the value of
-2°C(28.4°F)
|
4
|
Temperature control actuator
|
Open or Short
|
If
temperature setting 17°C-24.5°C, fix at maximum cooling
position. If temperature setting
25°C-32°C, fix at maximum heating position.
|
5
|
Mode control actuator
|
Open or Short
|
Fix
vent position, while selecting vent mode. Fix defrost position, while selecting all except
vent mode.
|
6
|
Intake control actuator
|
Open or Short
|
Fix
fresh position, while selecting fresh mode.
|
Fix
recirculation position, while
selecting recirculation mode.
|
7
|
R_NEngldlTgC
|
FFH
or non reception
|
|
8
|
N
|
non
reception
|
Control with the value of 650 RPM
|
9
|
F_N_ENG TCU)
|
1H
or non reception
|
Control with the value of 650 RPM
|
10
|
VS
|
FFh
or non reception
|
VS_TCU(TCU2), (VS,VS_TCUall FFH or non reception : A/C
OFF)
|
11
|
Temp _ ENG
|
FFh
or NO reception
|
Control with the value of - 2
°C(28.4°F)
|
12
|
TPS
(Throttle Position Signal)
|
FFh
or NO reception
|
5%
|
13
|
R_TqAcnApvC
|
FFh
or NO reception
|
A/C
OFF (0Nm)
|
14
|
R_PAcnC
|
FFh
or NO reception
|
A/C
OFF (0hpa)
|
15
|
RLY_AC
|
non
reception
|
A/C
OFF
|
16
|
Auto Defog Sensor
|
Open or Short
|
Control with the Humidity of 0%
|
17
|
Defog Door Potention Meter
|
Open or Short
|
VENT
Bi- Level MODE : Fix CLOSE positionwhile selecting all
except VENT Bi- Level mode. : Fix
OPEN position.
|
18
|
ECV
|
Open
|
CF_Fatc_EcvFlt = 01H(fault) ECV OFF, A/C
Output
Off.
|