Heated Oxygen Sensor
(HO2S) consists of the zirconium and the alumina and is installed on
upstream and downstream of the Warm-up Catalytic Converter
(WCC).
After it compares oxygen
consistency of the atmosphere with the exhaust gas, it transfers the
oxygen consistency of the exhaust gas to the ECM. When A/F ratio is rich
or lean, it generates approximately 1V or 0V respectively. In order that
this sensor normally operates, the temperature of the sensor tip is higher
than 370°C (698°F). So it has a heater which is controlled by the ECM duty
signal.
When the exhaust gas
temperature is lower than the specified value, the heater warms the sensor
tip.
|