Home
›
Engine Control/Fuel System
›
Engine Control System
›
Purge Control Solenoid Valve (PCSV)
Engine Control System › Purge Control Solenoid Valve (PCSV): Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the PCSV connector.
3.
Measure resistance between the PCSV terminals 1 and 2.
4.
Check that the resistance is within the specification.
Specification:
Refer to "Specification"
Removal
1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the purge control solenoid valve connector (A).
3.
Disconnect the vapor hoses (B) from the purge control solenoid valve.
4.
Remove the valve from the bracket.
Installation
•
Install the component with the specified torques.
•
Note that internal damage may occur when the component is dropped. If the component has been dropped, inspect before installing.
•
Be sure not to apply oil or lubricant to the end of the hoses when connecting the PCSV hose.
•
Be careful of foreign material not to flow into the valve.
1.
Installation is reverse of removal.
Purge control solenoid valve bracket installation bolt:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m 7.2 ~ 8.7 lb-ft)