Home › Engine Mechanical System › Lubrication System › Oil Level Gauge & Pipe

Lubrication System › Oil Level Gauge & Pipe: Repair procedures

Removal and Installation
1.
Remove the oil level gauge (A).

Tightening torque:
18.6 ~ 22.6N.m (1.9 ~ 2.3kgf.m, 13.7 ~ 16.6lb-ft)

When installing, apply engine oil to the O-ring and take care the O-ring not to be damaged.
Always use a new O-ring.
2.
Installation is in the reverse order of removal.