Home › Automatic Transaxle System › Automatic Transaxle Control System › Torque Converter Control Solenoid Valve (T/CON_VFS)

Automatic Transaxle Control System › Torque Converter Control Solenoid Valve (T/CON_VFS): Repair procedures

Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the solenoid valve connector.
3.
Measure resistance between sensor signal terminal and sensor ground terminal.
4.
Check that the resistance is within the specification.
Removal
1.
Remove the automatic transaxle assembly.
(Refer to Automatic Transaxle System - "Automatic Transaxle")
2.
Remove the air breeder hose (A).
3.
Remove the valve body cover (B).

Tightening torque:
12.8 ~ 14.7 N.m (1.3 ~ 1.5 kgf.m, 9.4 ~ 10.9 lb-ft)

4.
Remove the bolt (3ea) after disconnecting the solenoid valve connector (B) and the oil temperature sensor connector (A).

Tightening torque:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

5.
Remove the solenoid valve support bracket (B) and the valve body mounting bolt (A-1ea).

Tightening torque:
9.8 ~ 11.8 N.m (1.0 ~ 1.2 kgf.m, 7.2 ~ 8.7 lb-ft)

6.
Remove the torque converter control solenoid valve (A).

Installation
1.
Installation is the reverse of removal.
•
Adding automatic transaxle fluid.
(Refer to Hydraulic System - "Fluid")
•
Use new valve body gasket (A).