Home › Heating,Ventilation, Air Conditioning › Air Conditioning System › Ambient Sensor

Air Conditioning System › Ambient Sensor: Repair procedures

Inspection
1.
Ignition "OFF"
2.
Disconnect ambient temperature sensor.
3.
Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature.

1. Sensor Ground
2. Ambient Sensor Signal

Specification
Ambient temperature
[°C(°F)]
Resistance between terminals 1 and 2 (kΩ)
-30(-22)
480.41
-20(-4)
271.21
-10(14)
158.18
0 (32)
95.10
10 (50)
58.80
20 (68)
37.32
30(86)
24.26
40(104)
16.13
50(122)
10.95

4.
If the measured resistance is not specification, substitute with a known-good ambient temperature sensor and check for proper operation.
5.
If the problem is corrected, replace the ambient temperature sensor.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the under cover (A).

3.
Disconnect the connector and then remove the ambient temperature sensor (A).

4.
Installation is the reverse order of removal.