Home › Heating,Ventilation, Air Conditioning › Heater › Mode Control Actuator

Heater › Mode Control Actuator: Repair procedures

Inspection
1.
Ignition "OFF"
2.
Disconnect the connector of mode control actuator.
3.
Verify that the mode control actuator operates to the defrost mode when connecting 12V to the terminal 3and grounding terminal 7.
4.
Verify that the mode control actuator operates to the vent mode when connecting in the reverse.

1. -
2. -
3. Defrost mode
4. Sensor GND
5. Feedback signal
6. +5V (Vcc)
7. Vent

5.
Check the voltage between terminals 4 and 5.
Specification
Door position
Voltage(4-5)
Error detecting
Max. cooling
0.3 ± 0.15V
Low voltage :0.1V or less
Max. heating
4.7 ± 0.15V
High voltage :4.9V or more

It will feedback current position of actuator to controls.
6.
If the measured voltage is not specification, substitute with a known-good mode control actuator and check for proper operation.
7.
If the problem is corrected, replace the mode control actuator.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad left side cover (A).

3.
Remove the extension cover (A).

4.
Remove the fuse box cover (A).

5.
Remove the crash pad lower cover (A).

6.
Disconnect the diagnosis connector (A) and then remove the crash pad lower cover.

7.
Remove the shower duct (A).

8.
Disconnect the mode control actuator connector (A).

9.
Loosen the mounting screw and then remove the mode control actuator (B).
10.
Installation is the reverse order of removal.