Home
›
Heating,Ventilation, Air Conditioning
›
Blower
›
Intake Actuator
Blower › Intake Actuator: Repair procedures
Inspection
1.
Ignition "OFF".
2.
Disconnect the intake actuator connector.
3.
Verify that the actuator operates to the recirculation position when connecting 12V to the terminal 3 and grounding terminal 7.
4.
Verify that the intake actuator operates to the fresh position when connecting in the reverse.
1. -
2. -
3. Fresh
4. 5V (Vcc)
5. Feedback Signal
6. Sensor GND
7. Rec
5.
Check the voltage between terminals 5 and 6.
Specification
Door position
Voltage(5-6)
Error detecting
Recirculation
0.3 ± 0.15V
Low voltage :0.1V or less
Fresh
4.7 ± 0.15V
High voltage :4.9V or more
6.
If the intake actuator is not operated well, substitute with a known-good intake actuator and check for proper operation.
7.
If the problem is corrected, replace the intake actuator.
Replacement
1.
Disconnect the negative (-) battery terminal.
2.
Remove the crash pad.
(Refer to Body - "Main Crash Pad Assembly")
3.
Disconnect the Intake actuator connector (A).
4.
Loosen the mounting screw and then remove the intake actuator (B).
5.
Installation is the reverse order of removal.