| 1. |
Disconnect the negative (-) battery
terminal. |
| 3. |
Disconnect the panoramaroof motor (A)
connector.

|
| 4. |
Ground the terminals as below table, and
check that the panoramaroof unit operates.
| - |
When inspecting the panoramaroof
motor operation, panoramaroof motor and roller blind
motor always should be
connected. | |

A : Master connector / Panoramaroof
panel
B : Slave connector / Roller
blind |
| 5. |
Make these input tests at the connector. If
any test indicates a problem, find and correct the cause, then
recheck the system. If all the input tests prove OK, the
panoramaroof motor must be faulty; replace it.
Terminal
|
Test
condition
|
Test:
Desired result
|
3
|
IG2
ON
|
Check for voltage
to ground: There should be
battery voltage.
|
1
|
Under
all conditions
|
Check for
continuity to ground: There
should be continuity.
|
6
|
Under
all conditions
|
Check for voltage
to ground: There should be
battery
voltage.
|
|
| 6. |
Ground the terminals as below table, and
check that the roller blind motor operates.

|
| Resetting The
Panoramaroof |
Whenever the vehicle
battery is disconnected or discharged, or you use the emergency handle to
operate the panoramaroof, you have to reset your panoramaroof system as
follows :
| 1. |
Turn the ignition key to the ON position.
|
| 2. |
Close fully the panoramaroof for about 5
seconds and the blind for about 5 seconds.
|
| 3. |
Release the panoramaroof control
lever. |
| 4. |
Push the panoramaroof control lever forward
in the direction of close(about 10 seconds) until the panoramaroof
is moved a little. Then, release the
lever. |
| 5. |
Push the panoramaroof control lever forward
in the direction of close until the panoramaroof operates as
follows.
Blind open -> Tilt open -> Slide open
-> Slide close -> Blind close
Then, release the control
lever.
When this is complete, the panoramaroof
system is reset. |
Protecting
Motor From Overheating
In order to protect
the panoramaroof motor from overheating from continuous motor operation,
the panoramaroof ECU controls the Run-time and Cool-time of the motor as
follows:
| 1. |
The panoramaroof ECU detects the Run- time
of motor |
| 2. |
Motor can be operated continuously for the
1st run-time(120 ± 10sec.). |
| 3. |
The continuous operation of motor stops
after the 1st Run-time(120 ±
10sec.). |
| 4. |
Then Motor is not operated for the 1st
Cool-time(18 ± 2sec.). |
| 5. |
Motor is operated for the 2nd Run-time(10 ±
2sec.) at the continued motor operation after 1st Cool-time(18 ±
2sec.) |
| 6. |
The continuous operation of motor stops
operating after the 2nd Run-time(10 ±
2sec.) |
| 7. |
Motor is not operated for the 2nd
Cool-time(18 ± 2sec.). |
| 8. |
Motor repeats the 2nd run-time and 2nd
cool-time at the continued motor operation.
| A. |
In case that motor is not operated
continuously, the run-time is
increased. |
| B. |
The Run-Time of motor is initialized
to "0" if the battery or fuse is reconnected after being
disconnected, discharged or
blown. |

T1 : 120 ± 10 sec., T2 : 18 ± 2
sec.,
T3 : 10 ± 2 sec., T4 : 18 ± 2
sec. |