When reversing, the
driver may have difficult seeing the blind spots and determine the
distance from the object. In order to provide the driver safety and
convenience, back warning system will operate upon shifting to "R"
Ultrasonic sensor will emit ultrasonic wave rearward and detect the
reflected wave. Control unit will calculate distance to the object using
the sensor signal input and output buzzer alarm in three steps (first,
second and third alarm).
PAS consists of 8
sensors(Front 4 EA, Rear 4EA) which are detecting the obstacles and
transmit the result separated into three warning levels, the first, second
and third to IPM(BCM) by Lin communication. IPM(BCM) decides the alarm
level by the transmitted communication message from the slave sensors,
then operate the buzzer or transmits the data for display.
Block
Diagram

System
Operation Specification
| 1. |
Initial mode - Front sensor
| (1) |
System initializing time is 500ms
after IGN1+ initial D Gear + below 10 Km/h
. |
| (2) |
PAS recognizes LID and sets the sensor
ID up during initialization. |
| (3) |
PAS activates each sensor and then
executes the diagnosis after finishing initialization of
IPM(BCM). |
| (4) |
PAS Starting buzzer" is normally
worked, when sensor does not send an error message and after
finishing error diagnosis. |
| (5) |
If any failure is received from the
any sensors, PAS Starting Buzzer" does not work but the
failure alarm is operated for a moment.
If you have display option, warning
sign is also shown on it. |
| (6) |
Buzzer for sensor failure is operated
once, but display is shown continuously until it is repaired
completely. |
| (7) |
IPM(BCM) memorizes the completed
initializing status of front sensor until IGN 1 is OFF. It
doesn't activate initializing when next D gear
input. |
| (8) |
In case of PAS SW OFF, system
initializing does not be
activated. |
| (9) |
If PAS switch is ON like as below
status, it activates initializing.
| A. |
PAS switch OFF when IGN1 is
On. |
| B. |
PAS switch ON when vehicle speed
is below 10
km/h | |
| (10) |
Initializing has nothing to do with
parking brake
operation. | |
| 2. |
Initial mode - Rear sensor
| (1) |
System initializing time is 500ms
after IGN1+ initial R Gear. |
| (2) |
PAS recognizes LID and sets the sensor
ID up during initialization. |
| (3) |
PAS activates each sensor and then
executes the diagnosis after finishing initialization of
IPM(BCM). |
| (4) |
PAS Starting buzzer" is normally
worked, when sensor does not send an error message and after
finishing error diagnosis. |
| (5) |
If any failure is received from the
any sensors, PAS Starting Buzzer" does not work but the
failure alarm is operated for a moment.
If you have display option, warning
sign is also shown on it. |
| (6) |
Buzzer for sensor failure is operated
once, but display is shown continuously until it is repaired
completely. |
| (7) |
IPM(BCM) memorizes the completed
initializing status of rear sensor until IGN 1 is OFF. It
doesn't activate initializing when next R gear
input. |
| (8) |
Initializing has nothing to do with
parking brake
operation. | |
| 3. |
Normal mode - Front sensor
| (1) |
Lin communication starts and keeps the
routine after IGN1 ON+D gear + below 10
km/h. |
| (2) |
After initializing, the routine starts
at once without PAS starting warning
sound. |
| (3) |
Alarms of obstacle consists of 3 level
1,2,3 step and 1,2 alarm sounds intermittently and 3 alarm
sounds continuously. 1 level alarm doesn't exist in the front
ultrasonic sensor.
| • |
2 level alarm : Display is only
operated without alarm. |
| • |
3 level alarm : Alarm +
Display |
| B. |
Type without display : Alarm
only | |
| (4) |
In display, the data of each sensor is
sent from IPM(BCM) to display, for example cluster. CAN
communication is used for transmission and maximum gateway
time is 50ms. |
| (5) |
The efficient vehicle speed of RPAS
operation is under 10Km/h. |
| (6) |
It doesn't work at PAS SW
OFF. |
| (7) |
It has nothing to do with parking
brake operation. |
| (8) |
Operation doesn't start or stops at
gear N,
P. | |
| 4. |
Normal mode - Rear sensor
| (1) |
Lin communication starts and keeps the
routine after IGN1 ON+R gear |
| (2) |
BCM send a message once to each sensor
for operating request to check the initial status of the
system and four sensors response at a time. At this time, if
there is no problem, the alarm starts after 500ms of R gear
shifting at 300ms intervals. |
| (3) |
After initialization, normal mode
starts 100ms later after finishing alarm
output. |
| (4) |
Alarm for obstacles is divided into 3
levels.
The first and second are intermittent
sound, and the third alarms
continuously |
| (5) |
In display, the data of each sensor is
sent from BCM to display, for example Cluster.
CAN communication is used for
transmission and maximum gateway time is
50ms. |
| (6) |
It has nothing to do with vehicle
speed. |
| (7) |
When PAS SW is OFF, if gear R signal
is inputted, PAS SW is changed to
ON. |
| (8) |
It has nothing to do with parking
brake operation. |
| (9) |
Operation doesn't start or stops at
gear N,
P. | |
Sensing
Area
| 1. |
Measurement condition – PVC pole (diameter
75mm, length 3m), normal
temperature |
| 2. |
Distance range detected objects (Measured
directly in front of sensor)
| A. |
Front sensor
61cm(24in) ~ 10cm(39.4in) :
±15cm(5.9in)
31cm(12.2in) ~ 60cm(23.6in):
±15cm(5.9in)
Less than 20cm(7.9in) : ±
10cm(3.9in) |
| B. |
Rear sensor
81cm(31.9in) ~ 120cm(47.2in) :
±15cm(5.9in)
41cm(16.1in) ~ 80cm(31.5in):
±10cm(3.9in)
Less than 40cm(15.7in) : ±
10cm(3.9in) | |
Horizontal
Sensing Area

Vertical
Sensing Area

Distance
Measurement
Transmission and
Reception are executed with one sensor
(FL, FCL, FCR, FR, RL,
RCL, RCR, RR each sensor execution)

(FCL → FL, FCL → FCR,
FCR → FCL, FCR → FR, RCL → RL, RCL → RCR, RCR → RCL, RCR → RR Execution in
order)
With two or three
sensors, one of them sends the transmission and the others get the
reception.

| Direct and
Indirect Measurement at once |
With two or three
sensors, the one sensor performs both transmission and reception, and the
others perform only reception.

RPAS
alarm system
When the RPAS sensor
detects the object, warning is operated by audible alarm device as like
buzzer. RPAS sensor sends data to BCM with LIN communication and BCM
implements audible warning for each RPAS SENSOR by priority. And it
performs a role of gateway only when it sends visible alarm device such as
Cluster.
| -
|
Sensor buzzer/display information processing
method of BCM In case of RL/RR sensor information, the BCM handles
each sensor information directly about Display and buzzer output
function. Buzzer output of CL/CR sensor, BCM handles center
combination information by priority both sensor, Otherwise, about
fail display information,BCM send that to cluster each sensor
information. |
System
operation Spec - Front sensor
When the system has
the power (after IGN ON and D gear), MICOM checks every sensor channel. In
case it is not find any error, it sounds 500ms afterward. But it finds any
error even a sensor, it sounds buzzer corresponding fault sensor instead
of initial starting alarm. If PAS ON switch in OFF, system doesn't work.
Function for normal mode entrance is as below.

* In the initial mode,
IPM(BCM) judges only sensor fail.
With D gear, system
function is as below.

With D gear releasing,
system function is as below

System
Operation Spec - Rear sensor
When the system has
the power (after IGN ON and R gear), MICOM checks every sensor channel.In
case it is not find any error, it sounds 300ms buzzer 500ms afterward.But
it finds any error even a sensor, it sounds buzzer corresponding fault
sensor instead of initial starting alarm. Function for normal mode
entrance is as below

With R Gear, system
function is as below

With R gear releasing,
system function is as below

※acceptable error
range on waveform ±10%
Alarm
Output Specification classified by distance between sensors
Condition logic
according to priority of alarm level is as below. (the identical
sensor)

*α value
definition
| 1. |
low priority sensor off : α =
0ms |
| 2. |
low priority sensor is 1st warning level : α
< 340ms |
| 3. |
low priority sensor is 2nd warning level : α
< 170ms |
*β value
definition
| 1. |
low priority sensor is 1st warning level : β
= 1700ms |
| 2. |
low priority sensor is 2nd warning level : β
= 1700ms |
| 3. |
low priority sensor is 3rd warning level : β
= 700ms |
Alarm control by
sensing distance is as below
| 1. |
First warning area (Front: 61cm(24in) ~
100cm(39.4in), Rear: 81cm(31.9in) ~ 120cm(47.2in) )

|
| 2. |
Second warning area (Front: 31cm(12.2in) ~
60cm(23.6in), Rear: 41cm(16.1in) ~ 80cm(31.5in) )

|
| 3. |
Third warning area (Front: less than
20cm(7.9in). Rear: less than 40cm(15.7in))

|
| 4. |
Period of fault alarm
| (1) |
With visible display

| |
Visible
Alarm Indicator Specification.
When the system
operates, cluster lights the indicator as below figure.
When the system finds
an object, it lights indicator immediately.
| 1. |
Alarm level per distance - Front
sensor
| A. |
First step alarm : 61~100 cm(24~39.4
in) |
| B. |
Second step alarm : 31~60 cm(12.2~23.6
in) |
| C. |
Third step alarm : Less than 20 cm(7.9
in) |

|
| 1. |
Alarm level per distance - Rear
sensor
When the gear is applied to R, cluster
lights the indicator as below figure.When the system finds an
object, it lights indicator immediately. During sensing an object,
if there is no object, it lights indicator that is no alarm status
for two seconds and then turns out afterward detecting an
object.(But when it turns third step alarm to No alarm status, it
lights third step alarm for two second and turns out.)
| A. |
First step alarm : 81~120 cm(31.9~47.2
in) |
| B. |
Second step alarm : 41~80 cm(16.1~31.5
in) |
| C. |
Third step alarm : Less than 40
cm(15.7 in) |

* It only displays the position of detected
obstacle.
* Indicator flickers every 1 second at third
step alarm.
* Integrated display(FCL/FCR,
RCL/RCR) |
Error
Handling
Section
|
Error
recognition condition
|
Error
releasing condition
|
Initial
Routine
|
LIN BUS OFF sensing once
|
Error is not released in
initial mode.
|
Normal
Routine
|
LIN BUS OFF is sensed
times in a row
|
The fault is released
when BCM or LIN Master senses LIN BUS ON four times in a row in
normal mode
|
※ Remark :
| 1. |
In fault counting, output message or signal
should be transmitted as a Last Valid
value. |
| 2. |
Error in initial mode, fault buzzer (BCM) is
operated with fault
display(Cluster) |
| 3. |
Error in normal mode, fault is only
displayed on Cluster without
buzzer. |
| Sensor fault
(LIN Msg : 0x08) |
Section
|
Error
recognition condition
|
Error
releasing condition
|
Initial
Routine
|
Sensor fault Message
sensing once
|
Error is not released in
initial mode.
|
Normal
Routine
|
Sensor fault Message
sensing four times in a row
|
The fault is released
when BCM or LIN Master senses LIN BUS ON four times in a row in
normal mode
|
※ In fault display,
RCR/RCL indicator is displayed individually
※ Remark
:
| 1. |
In fault counting, output message or signal
should be transmitted as a Last Valid
value. |
| 2. |
Error in initial mode, fault buzzer (BCM) is
operated with fault display (Cluster)
|
| 3. |
Error in normal mode, fault is only
displayed on Cluster without buzzer
|
| 4. |
When the error occurs in direct condition,
the sensors sent the same status of error for indirect
condition |


Communication
Standard
This section defines
the communication between RPAS and BCM.
RPAS send a detecting
result of object and sensor diagnosis result to BCM according to this
document, and BCM takes a role to alarm.
Indicator shows the
transmitted position and alarm data, in alarm case, it finds the nearest
DATA and alarms the nearest DATA first.
(Ex. In case, RL is
first step alarm and RR is third step, RR alarm has
priority.)