| CHARGING REFRIGERANT SYSTEM
(VAPOR) |
This step is to charge
the system through the low pressure side with the refrigerant in a vapor
state. When the refrigerant container is placed right side up, refrigerant
will enter the system as a vapor.
| 1. |
Install the refrigerant can tap valve as
described in Handling the Refrigerant Service Tap Valve
section. |
| 2. |
Open the low pressure valve. Adjust the
valve so that the low pressure gauge does not read over 412 kPa (4.2
kg/cm, 60 psi). |

| 3. |
Put the refrigerant in a pan of warm water
(maximum temperature 40°C or 104°F) to keep vapor pressure in the
container slightly higher than vapor pressure in the
system. |
| 4. |
Run the engine at fast idle and operate the
air conditioning.
Be sure to keep the container upright to
prevent liquid refrigerant from being charged into the system
through the suction side, resulting in possible damage to the
compressor. |

| 5. |
Charge the system to the specified amount.
Then close the low pressure valve.
|
Specified amount : 730--
780g |
|
When
refrigerant charging speed is slow, immerse the refrigerant can in heated
water. (a temperature of approx. 40°C (104°F)).
| a. |
Under any circumstances, the refrigerant
must not be warmed in water heated to a temperature of over 52°C
(126°F). |
| b. |
A blow torch or stove must never be used to
warm up the can. |

CHARGING
THE REFRIGERANT SYSTEM (LIQUID)
This step is to charge
an empty system through the high pressure side with refrigerant in a
liquid state. When the refrigerant container is held upside down,
refrigerant will enter the system as a liquid.
Never run the engine
when charging the system through the high pressure side. Do not open the
low pressure valve when the system is being charged with liquid
refrigerant.

| 1. |
Close both high and low pressure valves
completely after the system is
evacuated. |
| 2. |
Install the refrigerant can tap valve as
described in "Handling the Refrigerant Service Tap Valve"
section. |
| 3. |
Open the high pressure valve fully and keep
the container upside down. |
| 4. |
Charge the system to the specified amount by
weighing the refrigerant with a scale. Overcharging will cause
discharge pressure (high side) to rise. Then, close the high
pressure valve.
|
Specified amount : 630 --
680g |
If the low pressure gauge does not show a
reading, the system is restricted and must be repaired.

|
| 5. |
After the specified amount of refrigerant
has been charged into the system, close the manifold gauge
valve. |
| 6. |
Confirm that there are no leaks in the
system by checking with a leak detector. Refer to Checking
Refrigerant Leak.
Conducting a performance test prior to
removing the manifold gauge is good service
practice. |