Home
›
Heating, Ventilation & Air Conditioning
›
Air Conditioning System
›
Refrigerant System
Air Conditioning System › Refrigerant System: REFRIGERANT DISCHARGING PROCEDURE
REFRIGERANT DISCHARGING PROCEDURE
a.
Connect the manifold gauge set to the system.
b.
Put a towel under the open end of the center hose.
c.
Open the high pressure hand valve slowly to discharge the refrigerant slowly.
If discharging the refrigerant is too fast, compressor oil may drain from the system.
d.
Check if a towel is stained with oil. If so, gently lock the hand valve.
e.
If the manifold gauge reading drops below 3.5kg/cm, open the low pressure hand valve slowly.
f.
Open the high and low pressure hand valve slowly in order to drop the system pressure until the gauge indicates 0kg/cm.