THERMISTOR
AND PIN SENSOR
The
thermistor and pin sensor will detect the core temperature and
interrupt the compressor relay power to prevent evaporator freezing by
excessive cooling.
The
thermistor and pin sensor will use the thermal negative
characteristic.

| 1. |
Thermistor (MANUAL)
| c. |
Turn on the air
conditioner. |
| d. |
Using the multi-tester, check the
output voltage at terminals 2 and 3 of the
thermistor. | |
|
Thermistor |
Operating temperature |
Output voltage |
|
ON |
0.5 ± 0.5°C |
12V |
|
OFF |
2.5 ± 0.5°C |
0V |
| 2. |
Pin sensor (AUTOMATIC)
| a. |
This is the same method as the
thermistor to check the pin
sensor. | |
Pin sensor
temperature-resistance-output voltage characteristics
|
Temp (°C) |
Resistance (KΩ) |
Output (V) |
Temp (°C) |
Resistance (KΩ) |
Output (V) |
|
-5 |
14.23 |
3.2 |
15 |
6 |
2.14 |
|
-2 |
12.42 |
3.04 |
20 |
4.91 |
1.9 |
|
0 |
11.36 |
2.93 |
25 |
4.03 |
1.67 |
|
2 |
10.4 |
2.83 |
30 |
3.34 |
1.47 |
|
5 |
9.12 |
2.66 |
35 |
2.78 |
1.29 |
|
10 |
7.38 |
2.4 |
40 |
2.28 |
1.11 |