Home › Heating, Ventilation & Air Conditioning › Blower Controls › Water Temperature Sensor

Blower Controls › Water Temperature Sensor: INSPECTION

WATER TEMPERATURE SENSOR
1.
The water temperature sensor is located at the heater core, and detects coolant temperature flowing through heater core. It is an NTC device: resistance will rise with lower temperature, and drop with higher temperature.
CHECK
Water temperature
Resistance
25°C
10KΩ
60°C
2.50KΩ

2.
Electromotive heating control
In AUTO mode, discharge mode to the FLOOR or Bi-LEVEL, if the coolant temperature is low, the sensor will the prevent cold air from being discharged toward passenger's legs.
a.
Operation control
1)
Discharge mode FLOOR or Bi-LEVEL with AUTO setting
2)
Coolant temperature is low
b.
System operation
1)
Mode door : DEF-->MIX-->AUTO
2)
Blower level : AUTO LO-->AUTO HI
3)
Intake door : Ambient air
c.
Override operation conditions
1)
After the ignition is on for 10 minutes.
2)
Coolant temperature is high.
3)
Upon selecting blower mode manual operation, it will release the selected mode only. Upon selecting auto mode, it will re-enter the selected mode.
4)
If the mode is released by the system it will not reset.
5)
It will prevail over max. hot feature.