| 1. |
The A.Q.S. sensor, located at the center
support in front of the engine radiator, detects hazardous
elements in ambient air and provides output signals to the
control module. |
| 2. |
It will detect sulfurous acid gas, carbon
dioxide, carbon monoxide, hydrocarbon and
allergen.
SENSOR OUTPUT
|
Condition |
Resistance |
|
Normal condition |
5V |
|
Hazardous gas
detection |
0V |
|

|