| 1. |
Check the fusible plug and fittings for
leakage, using a leak detector. |
| 2. |
Run the engine at fast idle with the air
conditioningON, and check both the inlet and outlet temperature. If
difference in temperatures between the inlet and outlet is large,
replace the receiver-drier. |

| a. |
Plug all open fittings immediately to keep
moisture out of the system. |
| b. |
Do not remove the blind plugs until ready
for connection. |
| c. |
If the receiver-drier is replaced with a new
unit, add 40cc of compressor oil to the
compressor. |
| d. |
Evacuate, charge and test the refrigeration
system. | |