If the MFI
system components (sensors, ECM, injector, etc.) fail, interruption to the
fuel supply or failure to supply the proper amount of fuel for various
engine operating conditions will result. The following situations may be
encountered.
| a. |
Engine is hard to start or does not start at
all. |
If any of the
above conditions are noted, first perform a routine diagnosis that
includes basic engine checks (ignition system malfunction, incorrect
engine adjustment, etc.). Then, inspect the MFI system components with the
HI-SCAN (Pro).
| a. |
Before removing or installing any part, read
the diagnostic trouble codes and then disconnect the battery
negative (-) terminal. |
| b. |
Before disconnecting the cable from battery
terminal, turn the ignition switch to OFF. Removal or connection of
the battery cable during engine operation or while the ignition
switch is ON could cause damage to the
ECM. |
| c. |
The control harnesses between the ECM and
heated oxygen sensor are shielded with the shielded ground wires to
the body in order to prevent the influence of ignition noises and
radio interference. When the shielded wire is faulty, the control
harness must be replaced. |
| d. |
When checking the generator for the charging
state, do not disconnect the battery '+' terminal to prevent the ECM
from damage due to the voltage. |
| e. |
When charging the battery with the external
charger, disconnect the vehicle side battery terminals to prevent
damage to the ECM. |
Malfunction
Indicator Lamp (MIL)
OBD-II
>
A malfunction
indicator lamp illuminates to notify the driver that there is a problem
with the vehicle. However, the MIL will go off automatically after 3
subsequent sequential driving cycles without the same malfunction.
Immediately after the ignition switch is turned on (ON position - do not
start), the MIL will illuminate continuously to indicate that the MIL
operates normally.
Faults with
the following items will illuminate the MIL
| c. |
Manifold Absolute Pressure
Sensor |
| d. |
Intake Air Temperature
Sensor |
| e. |
Engine Coolant Temperature
Sensor |
| f. |
Throttle Position
Sensor |
| g. |
Upstream Oxygen
Sensor |
| h. |
Downstream Oxygen Sensor
Heater |
| i. |
Downstream Oxygen
Sensor |
| j. |
Upstream Oxygen Sensor
Heater |
| m. |
Crankshaft Position
Sensor |
| n. |
Camshaft Position
Sensor |
| o. |
Evaporative Emission Control
System |
| w. |
Differential Pressure
Sensor |

INSPECTION>
| a. |
After turning ON the ignition key, ensure
that the light illuminates for about 5 seconds and then goes
out. |
| b. |
If the light does not illuminate, check for
an open circuit in the harness, a blown fuse or a blown
bulb. |
Self-Diagnosis
The ECM
monitors the input/output signals (some signals at all times and the
others under specified conditions). When the ECM detects an irregularity,
it records the diagnostic trouble code, and outputs the signal to the Data
Link connector. The diagnosis results can be read with the MIL or HI-SCAN
(Pro). Diagnostic Trouble Codes (DTC) will remain in the ECM as long as
battery power is maintained. The diagnostic trouble codes will, however,
be erased when the battery terminal or the engine control module (ECM)
connector is disconnected, or by the HI-SCAN (Pro).
If a sensor connector
is disconnected with the ignition switch turned on, the diagnostic trouble
code (DTC) is recorded. In this case, disconnect the battery negative
terminal (-) for 15 seconds or more, and the diagnosis memory will be
erased.