[FOR SHORT-TERM FUEL TRIM]
The ECM will set a code and the Malfunction
Indicator Lamp (MIL) will turn on if the short-term fuel trim value
goes 10% to 15% rich [for P1123] or if the short-term fuel trim
additive value is less than 0.4 milliseconds, or 10% to 15% lean
[for P1124] for 30 seconds during two driving cycles when the
following conditions are met:
| a. |
ECM is in closed loop
operation. |
| b. |
Engine speed is below 1000
RPM. |
| c. |
Engine coolant temperature is above
158°F (70°C). |
| d. |
Canister purge system is not
operating. |
| e. |
Mass air flow is less than 7.5 g/s
[for P1123] or 5.5 g/s [for
P1124]. |
[FOR LONG-TERM FUEL TRIM]
The ECM will set a code and the Malfunction
Indicator Lamp (MIL) will turn on if the long-term multiplicative
value is less than 77% for 30 seconds [for P1127] or if the
long-term fuel trim value goes to 10% to 15% lean [for P1128] for 30
seconds during two driving cycles when the following conditions are
met:
| a. |
Engine load exceeds 1.8
milliseconds. |
| b. |
ECM is in closed loop operation [for
P1127]. |
| c. |
Engine coolant temperature is above
158°F (70°C). |
| d. |
Canister purge system is not
operating. |
| e. |
Mass air flow is less than or 5.5
g/s. |
| f. |
Engine speed is below 1000 RPM [for
P1128]. | |