Home › Brake Systems › Conventional Brake System › Brake Pedal

Conventional Brake System › Brake Pedal: SERVICE INSPECTION AND ADJUSTMENT

SERVICE BRAKE PEDAL INSPECTION AND ADJUSTMENT
1.
Turn the stop lamp switch until the clearance between the stop lamp switch outer case and pedal arm reaches the standard value, and secure the stop lamp switch with the lock nut.
Clearance between pedal and stop lamp switch A
0.5-1.0 mm (0.02-0.039 in.)

2.
Free play of brake pedal.
Brake pedal free play B :
3-8 mm (0.117-0.312 in.)