When disconnecting the
vacuum hose, make an identification mark on it so that it can be
reconnected to its original position.
| 1. |
Disconnect the vacuum hose from the solenoid
valve. |
| 2. |
Detach the harness
connector. |
| 3. |
Connect a vacuum pump to the nipple to which
the red-striped vacuum hose was
connected. |
| 4. |
Apply vacuum and check when voltage is
applied to the evaporative emission canister purge solenoid valve
and when the voltage is discontinued.
|
Battery voltage |
Normal condition |
|
When applied |
Vacuum is released. |
|
When discontinued |
Vacuum is
maintained. |
|

| 5. |
Measure the resistance between the terminals
of the solenoid valve.
|
Evaporative emission canister purge
solenoid valve
Coil resistance:
26Ω[at 20° C(68°
F)] |
|