The specific
gravity of battery electrolyte changes with temperature. Heat thins the
solution and lowers the specific gravity. Cold thickens the solution and
raises the specific gravity.
A fully
charged battery should have a specific gravity between 1.260 and 1.280,
with the electrolyte temperature at 26.7°C. The specific gravity reading
must be corrected by adding 4 points (.004) for each 5.56°C above 26.7°C
or subtracting 4 points for every 5.56°C below 26.7°C.
For example :
The hydrometer reading is 1.280, and the electrolyte temperature reading
is 5.56°C. According to the chart below, the specific gravity must be
lowered by 0.028 points. The true corrected reading is 1.252.
1.280 - 0.028
= 1.252
You should
never take a hydrometer reading immediately after water has been added.
The water and electrolyte must be mixed by either charging for a few
minutes at a low rate or by allowing the battery to sit for an hour.
A difference of 50
points (0.050) or more between one or more cells indicates a defective
battery. It should be replaced.
|