| VOLTAGE DROP TEST OF GENERATOR OUTPUT
WIRE |
This test
determines if the wiring between the generator "B" terminal and the
battery (+) terminal is good by the voltage drop method.
PREPARATION
| 1. |
Turn the ignition switch to
"OFF."
To identify connection problems, be sure not
to disturb either of the two terminals or their connections during
this test. |
| 2. |
Connect a digital voltmeter between the
generator "B" terminal and battery (+) terminal. Connect the (+)
lead wire of the voltmeter to the "B" terminal and the (-) lead wire
to the battery (+) terminal. |
CONDITIONS
FOR TESTING
With the
engine running and headlamps, blower motor etc. ON, check the reading on
the voltmeter.
RESULT
| 1. |
The voltmeter should read a standard
0.3V. |
| 2. |
If the reading is above 0.3V, poor wiring
should be suspected.
Check wiring from generator 'B' terminal
through the fusible link to the battery (+) terminal.
Check for loose wiring or color change from
an overheated harness. Correct and check
again. |
| 3. |
On completion of the test, set the engine at
idle.
Then turn off the headlamps, blower motor
etc., and ignition. |