Air Conditioning System › Refrigerant System: PERFORMANCE TEST
PERFORMANCE TEST
1.
Install the manifold gauge
set.
2.
Run the engine at 2,000 rpm and set the
controls for maximum cooling and high blower
speed.
3.
Keep all windows and doors
open.
4.
Place a dry-bulb thermometer in the cool air
outlet.
5.
Place a wet-dry thermometer close to the inlet
of the cooling unit.
6.
Check that the reading on the high pressure
gauge is 1,373-1,575 kPa (14-16 kg/cm², 199-228 psi). If the reading
is too high, pour water on the condenser. If the reading too low,
cover the front of the condenser.
7.
Check that the reading on the dry-bulb
thermometer at the air inlet at 25-35°C
(77-95°F).
8.
Calculate the relative humidity from the
psychrometric graph by comparing the wet-and dry-bulb reading at the
air inlet.
9.
Measure the dry-bulb temperature at the cool
air outlet, and calculate the difference between the inlet dry-bulb
and outlet dry-bulb temperatures.
10.
Check that the intersection of the relative
humidity and temperature difference falls within the block below. If
the intersection is within the block, cooling performance is
satisfactory.