Home › Heating, Ventilation & Air Conditioning › Blower Controls › Air Conditioning Switch

Blower Controls › Air Conditioning Switch: SWITCH OPERATION AND FEATURES

SWITCH OPERATION AND FEATURES
a.
Full auto air conditioning system: One-touch button type.
b.
Manual air conditioning system: Combination of dial switch and a one-touch button.
Control panel switches will generate buzzer sound on operation
Button
Function
Display
System operation
Stop switch and system operation
Temperature switch (Temperature control) (Manual airconditioning systems have dial type switches)
Temperature setting UP/DOWN
Temperature setting indication Range: 17°C-32°C
Scale: 0.5°C
User may chose the temperature indication between °C/°F.
17°C = 62°F
32°C = 90°F
25°C = 77°F
a.
The switch will operate the temperature door to regulate the cool/warm air ratio and, resultingly, control the discharge air.
b.
The switch will raise or lower the temperature by 0.5° increments.
c.
Setting at 17°C (62°F) will provide max. cooling, and setting at 32°C (90°F) will provide max. heating.
d.
Switching off-->on, it will display the temperature setting just before the previous switching-off.
e.
In shifting 17.5°C-->17°C or 31.5°C-->32°C, raising temperature setting will generate buzzer sound 5 times at interval of 0.15 seconds.
f.
Lowering the temperature setting at 17°C or raising the temperature setting at 32°C, will generate buzzer sound 5 times at intervals of 0.15 sec.
g.
Pressing on repeatly : Shifts one unit every 0.7 second.
Holding down: First shift in 0.7 seconds, then shift every 0.3 seconds (buzzer sound for 0.1 second upon each shift)
a.
Turning off the switch, the system will be off.
b.
Control temperature setting up/down.

Button
Function
Display
System operation
Stop switch and system operation
AUTO (Auto control)
Auto control of air conditioning system
"AUTO" will be displayed on control panel.
a.
The system will provide auto control of the features below on the basis of temperature setting:
1)
Temperature door
2)
Mode door
3)
Intake door (Shift between fresh air/recirculation)
4)
Blower speed
5)
Compressor.
b.
"AUTO" will disappear upon releasing the AUTO switch.
c.
Features, except manually selected switches, will be controlled automatically upon releasing the auto switch.
a.
Off : system off
b.
Blower switch : Manually controls blower
c.
MODE : Manually controls discharge mode
d.
A/C : Manually controls compressor on/off.
e.
Fresh air : Manually controls fresh air
f.
Recirculation : Manually controls recirculation
g.
Defroster : Manually controls defroster (when air conditioning system is on and recirculation selected)
AMB
Indicates ambient air temperature
'AMB' lamp will come on to indicate ambient air temperature. Other lamps will go out.
a.
Pressing the AMB switch, any previous indications will go out and the AMB lamp and the ambient air temperature will come on for 5 seconds, and then it will return to the previous indication just before pressing the AMB switch.
a.
AMB: Pressing the AMB switch when ambient air temperature is indicated, the ambient air temperature indication will extinguish.
b.
Other switches: Pressing another switch when the ambient air temperature is indicated, the ambient air temperature indication will extinguish and the selected switch control will be performed.
INTAKE
Recirculation
Recirculation lamp will come on. "AUTO" lamp will go out.
Fix intake door at the recirculation position.
a.
REC.S/W : FRE./REC. mode control
b.
OFF S/W : Fixing at the current condition (manual selection is possible)
c.
AUTO : Auto control (fresh air, recirculation)
Fresh air
Fresh air lamp will come on. "AUTO" lamp will go out.
Fix intake door at the fresh air position.
Blower fan speed UP/DOWN
Blower fan speed, UP/DOWN control
Indicates fan operation on/off
a.
Pressing fan UP/DOWN during auto control, the speed will shift up/down based on the current fan level.
b.
Switching on a switch, except the fan switch at 'off' condition, the speed will rise steadily from LOW to the target speed. (Requires 6 seconds from LOW to HI).
c.
Shifting a step will take 0.7 seconds when pressing the switch once. Holding the switch, a shift will occur every 0.3 seconds and buzzer sounds for 0.1 second.
d.
Pressing UP switch at HI position or DOWN switch at LOW position, will cause buzzer to sound 5 times at 0.4 second intervals.
a.
AUTO: Auto control
b.
OFF : System off
c.
Fan speed control: Manual control of blower fan speed.
Output increment step by step
Fan speed levels and voltages
a.
Auto cooling : No level (4.5V - B+)
b.
Auto heating: No level (4.5V - B+)
c.
Manual control: 7 levels (3.8V - B+)
A/C (Air conditioning switch)
Compressor on/off control
a.
A/C lamp (on/off)
b.
AUTO lamp off
Air conditioning on/off
a.
A/C: A/C on/off, manual control.
b.
OFF: System off AUTO: Auto control.
c.
DEF: Defroster, manual control.
MODE (Discharge mode)
Mode door control
a.
VENT
b.
FLOOR
c.
B/L
d.
MIX
MODE indication (on/off)
AUTO lamp off
a.
Fix mode door at B/L or MIX
b.
Manual operating mode switch, the switch will shift in the order of VENT-B/L-FLOOR-MIX
a.
MODE: Shift control in order of Vent-B/L-Floor-Mix-Vent.
b.
DEF: Defroster, manual control.
c.
AUTO: Auto control
A/C may be turned on at MIX mode enabling to turn off the switch to A/C position.
DEF (Defroster)
a.
Removes moisture/frost on windshield.
DEF control
a.
DEF indication on
b.
A/C lamp on
c.
INTAKE IND off
d.
AUTO lamp off
a.
Mode door: Fixed at defroster.
b.
Intake door: Fresh air control (Selecting recirculation is enabled).
c.
A/C: on (Compressor will be controlled on/off based on detected temperature by fin sensor).
d.
Prevails over max. cooling and max. heating.
e.
Prevails over mix mode control
a.
AUTO: System auto control.
b.
MODE: Discharge mode, manual control (release the defroster control).
c.
A/C: A/C on/off, manual control
d.
DEF: Returns to the previous condition before selecting DEF switch.
OFF
System off
a.
Control panel LCD off
b.
Indicator lamps on
a.
Blower fan speed off.
b.
Air conditioning off.
c.
Intake door: Fixed at the location prior to system off.
d.
Temperature door: Auto control.
e.
Mode door: Fixed at the condition prior to system off.
f.
AMB
Pressing the AMB switch after system off, 'AMB' lamp/ambient air temperature will come on for 5 seconds and then go out.
a.
AUTO: Auto control.
Blower speed: Return to MANUAL LOW.
b.
Others: Return to the previous condition before system off
A/C: Airconditioning on.
Others: Return to the previous condition before system off (Blower speed: Return to MANUAL LOW)
a.
INTAKE (recirc/fresh air) control at the system off condition
1)
Selecting the fresh air switch at the recirculation position after system off: It will shift to the fresh air position and extinguish the recirculation indicator lamp. The LCD will be held off.
2)
Selecting the recirculation switch at the fresh air position after system off: It will shift to the recirculation position and extinguish the recirculation indicator lamp. The LCD will be held off.
3)
Other switches will be held off at the above condition.
a.
MODE: Held at the previous condition before system off. (Auto control is released).
b.
Others: Return to the previous condition before system off (Blower speed: Return to MANUAL LOW)
a.
DEF: Shift to defroster mode
b.
Air conditioning : on
c.
Intake (fresh air)
d.
Others: Return to the previous condition before system off
a.
TEMP: Held at the previous condition before system off.
b.
Others: Return to the previous condition before system off.
DEFOG
Rear glass defogger on
Defogger switch indicator on/off
a.
Pressing the DEFOG switch, the switch signal will be sent to ETACS.
b.
Pressing the switch again, defogging will stop and the indicator will go out.
c.
Released by ETACS after 15 minutes of control.
Pressing DEFOG switch again, it will be released.
AQS switch
Air Quality System
AQS indicator on/off
The AQS indicator will come on and intake control (intake door) will be affected depending on the AQS signal.
Selection buttons are provided individually for AQS, recirculation and fresh air.
a.
Pressing the switch again when the switch is on: it will be released (Indicator will go out).
b.
Selecting fresh air or recirculation during AQS is on, AQS will be off and shift to the selected mode.
How to change temperature display mode on control panel LCD:
a.
Holding AMB button pressed, TEMP DOWN condition of 3 seconds or longer will shift the unit from °C to °F.
b.
Switching on battery power from off condition, the default unit, °C will be displayed.

SYSTEM CONTROL FEATURES
Signal I/O for each control feature
Control item
Input
Output
Remarks
Required discharge temperature control
Auto SW, A/C SW, TEMP SW, INCAR sensor, AMB sensor, Photo sensor, Water temperature sensor, thermo sensor, TEMP actuator.
TEMP actuator
Mode control
AUTO SW, MODE SW, TEMP SW, DEF SW, Blower SW, OFF SW, INCAR sensor, AMB sensor, Photo sensor, Water temperature sensor, thermo sensor, Power TR.
Blower motor
Power TR
HI-blower relay
Blower Switch
Manual selection
Control in priority
Mode door control
AUTO SW, MODE SW, DEF SW, Blower SW, OFF SW, TEMP SW, INCAR sensor, AMB sensor, Photo sensor.
Mode actuator
Intake control
AUTO SW, A/C SW, DEF SW, TEMP SW, OFF SW, Intake SW, INCAR sensor, AMB sensor, Photo sensor, Power TR.
Mode actuator
Compressor control
AUTO SW, A/C SW, DEF SW, TEMP SW, OFF SW, IN-CAR sensor, AMB sensor, Photo sensor
Compressor relay

a.
During mode control, the A/C may operate during DEF or MIX mode. In order to enable dehumidification, the driver may select A/C OFF during the A/C on condition.
Control specification
Control item
Control features
Remarks
Required discharge temperature
Required temperature determined by temperature setting and sensor inputs.
Auto control
Required discharge temperature is determined by temperature setting and each sensor input. The feature will use the required discharge temperature to perform auto control of temp. actuator, mode actuator, intake actuator, blower motor and compressor, and maintain temperature setting stably.
IN-CAR temperature correction
Upon detecting rapid changes of temperature from the INCAR sensor, it will gradually correct the incar temperature value.
a.
1°C UP/4sec delay
b.
1°C DOWN/4sec delay
AMB temperature correction
Upon detecting rapid changes of temperature from the AMB sensor, it will gradually correct the ambient temperature value.
a.
1°C UP/3min delay
b.
1°C DOWN/4sec delay
Photo correction
Upon detecting rapid changes of photo intensity from the PHOTO sensor, it will gradually correct the photo intensity value.
a.
350-->1000(W/m²)/1min delay
b.
350-->1000(W/m²)/5min delay
TEMP door control
Automatic control to maintain the optimum TEMP door opening (0% - 100%) it will be computed by the temperature setting and the input signal from each sensor.
Temperature setting range 17°C-->32°C, 0.5°C step (62°F-->90°F, 1°F step)
Blower speed
Automatic control of the blower speed. The target value will be computed by the temperature setting and the input signal from each sensor. (7 levels may be selected in case of manual selection.)
a.
Auto mode blower low voltage (Manual low voltage: 3.8)
b.
Auto mode HTR blower HI speed: 10.6V
Electro-motive mode control
During auto control it will raise permitted voltage of blower motor gradually in order to improve comfortability.
6 seconds for shifting LO-->MAX HI
Photo compensation
During auto control, it will compensate blower level and discharge temperature according to the photo intensity detected from the PHOTO sensor at VENT or B/L mode. PHOTO compensation will begin 5 seconds after ignition on.
Mode door control
Automatic control of air discharge based on the required discharge temperature. It will be computed by the temperature setting and the input signal from each sensor.
(VENT-->B/L-->FLOOR-->VENT)
In case of manual selection (VENT-->B/L-->FLOOR-->MIX-->VENT)
a.
Upon switching the system off in auto mode, mode door will maintain auto control condition.
b.
Upon switching the system off in manual mode, mode door will maintain manual control condition.
MIX mode control (in auto control)
If the ambient temperature is -13°C or less in AUTO mode, discharge mode will be controlled at MIX. (When front window glass is defogged.)
Entering MIX mode, A/C will operate.
INTAKE door control
Auto control of intake mode based on the required discharge temperature that will be computed by the temperature setting and the input signal from each sensor.
a.
Shift to REC upon selecting REC button at FRE condition (LED on).
b.
Shift to FRE upon selecting FRE button at REC condition (LED on).
INTAKE control upon switching system off
The intake door will shift to the REC position when switching the system off in auto-condition, and maintain the previous condition upon switching system off at manual condition.
a.
F/R manual selection will be enabled upon switching system off.
b.
REC indicator will come on upon switching system off at auto condition.
Compressor auto control
Auto control of the compressor on/off state based on the temperature setting and the input signal from each sensor.
a.
Auto control of compressor on/off upon selecting AUTO SW.
b.
Compressor on upon manually selecting DEF SW.
Compressor clutch on/off control based on refrigerant temperature
If EVAP sensor detects temperature of 0.5°C or less, and the temperature is 3°C, or higher, with the compressor off, the compressor will be on.
MAX HOT
Selecting the temperature setting at 32°C in auto mode, MAX HOT will be performed. It will prevail over MIX mode control.
a.
TEMP door: MAX HOT position
b.
MODE door: FLOOR mode
c.
INTAKE door: FRE mode
d.
Compressor: off
e.
Blower speed: auto HI(10.6V)
MAX COOL
Selecting the temperature setting at 17°C in auto mode, MAX COOL will be performed.
a.
TEMP door: MAX COOL position
b.
MODE door: FLOOR mode
c.
INTAKE door: REC mode
d.
Compressor: On
e.
Blower speed: MAX HI
Electromotive heating control
If the temperature setting>the IN-CAR temperature by 3°C at B/L or FLOOR in AUTO mode, and the temperature sensor input is 68°C or less, it will effect the electromotive heating control to prevent outside cold air from flowing toward the feet of passengers.
a.
Blower speed: Controlled at AUTO LOW (0.5V)
As coolant temperature rises, the MODE door will shift to DEF-->MIX-->AUTO.
Releasing condition
10 minutes after ignition on(In case of temperature sensor fail, it will apply substitute value, 20°C).
Upon pressing blower switch when water temperature sensor detection is 58°C or higher.
Upon pressing MODE switch.Upon pressing DEF switch.
MODE: Manual selection is enabled.
INTAKE door: As AUTO control or at manual selection mode.
Blower speed: Manual selection is enabled (No re-entry).
Electromotive cooling control
In order to prevent hot air from the VENT or B/L in AUTO mode (A/C on mode), the blower speed will be held at LOW for approx. 9 seconds before entering the AUTO control if the EVAP sensor detection is 30°C or higher.
MAX HOT
If the said condition is satisfied, electromotive cooling control will operate at any time.
Air Quality System (AQS)
The AQS system will detect hazardous elements and odors contained in the air. If the harmful element concentration is higher than standard, the system will output a LOW signal (0V) to the FATC.
a.
Upon initial battery connection and ignition on, it will operate at AUTO mode. (AQS will not operate.)
If the concentration is within the standard value, the system will output a HI signal (3V) the FATC.
a.
Upon IGN 2 ON, the AQS assembly will be preheated for 34.5±5seconds. During the preheating, AQS will output 0V (ground). (REC mode)
Depending on the signal from the AQS, the in FATC will control the INTAKE door as follows to prevent the inflow of harmful gas:
a.
IGN2 ON: It will check circuit break on the AQS assembly's signal line for approx 7 seconds during the preheating, irrespective to the AQS switch condition.
Condition
INTAKE door position
a.
When AQS is selected prior to IGN2 OFF and IGN2 is turned off-->on: AQS indicator will come on, and the system will operate at AQS mode. (Store the previous condition before IGN 2 OFF)
LOW
REC
HI
FRE
Initialization Upon battery-on
Upon initial power supply, it will operate in the initial condition.
a.
Upon initial ignition on after battery connection, the system will operate at temperature setting 25°C and at AUTO mode.
Memory
Upon removing ignition key, it will store FATC's operating condition
Turning ignition off and on again during FATC operation, the system will operate at the previous before the ignition off.