Home › Heating, Ventilation & Air Conditioning › Full Auto A/C Compressor Controls › Air Conditioning Switch

Full Auto A/C Compressor Controls › Air Conditioning Switch: SWITCH OPERATION AND FEATURES

SWITCH OPERATION AND FEATURES
a.
Full auto air conditioning system: One-touch button type.
b.
Manual air conditioning system: Combination of dial switch and a one-touch button.
Control panel switches will generate buzzer sound on operation
Button
Function
Display
System operation
Stop switch and system operation
Temperature switch (Temperature control) (Manual airconditioning systems have dial type switches)
Temperature setting UP/DOWN
Temperature setting indication Range: 17°C-32°C
Scale: 0.5°C
User may chose the temperature indication between °C/°F.
17°C = 62°F
32°C = 90°F
25°C = 77°F
a.
The switch will operate the temperature door to regulate the cool/warm air ratio and, resultingly, control the discharge air.
b.
The switch will raise or lower the temperature by 0.5° increments.
c.
Setting at 17°C (62°F) will provide max. cooling, and setting at 32°C (90°F) will provide max. heating.
d.
Switching offon, it will display the temperature setting just before the previous switching-off.
e.
In shifting 17.5°C17°C or 31.5°C32°C, raising temperature setting will generate buzzer sound 5 times at interval of 0.15 seconds.
f.
Lowering the temperature setting at 17°C or raising the temperature setting at 32°C, it will generate buzzer sound 5 times at interval of 0.15 sec.
g.
Pressing repeatly on: Shifts one unit every 0.7 second.
Holding down: First shift in 0.7 seconds, then shift every 0.3 seconds (buzzer sound for 0.1 second upon each shift)
a.
Turning off the switch, the system will be off.
b.
Control temperature setting up/down.

Button
Function
Display
System operation
Stop switch and system operation
AUTO (Auto control)
Auto control of air conditioning system
"AUTO" will be displayed on control panel.
a.
The system will provide auto control of the features below on the basis of temperature setting:
1)
Temperature door
2)
Mode door
3)
Intake door (Shift between fresh air/recirculation)
4)
Blower speed
5)
Compressor.
b.
"AUTO" will disappear upon releasing the AUTO switch.
c.
Features, except manually selected switches, will be controlled automatically upon releasing the auto switch.
a.
Off : system off
b.
Blower switch : Manually controls blower
c.
MODE : Manually controls discharge mode
d.
A/C : Manually controls compressor on/off.
e.
Fresh air : Manually controls fresh air
f.
Recirculation : Manually controls recirculation
g.
Defroster : Manually controls defroster (when air conditioning system is on and recirculation selected)
AMB
Indicates ambient air temperature
'AMB' lamp will come on to indicate ambient air temperature. Other lamps will go out.
a.
Pressing the AMB switch, any previous indications will go out and the AMB lamp and the ambient air temperature will come on for 5 seconds, and then it will return to the previous indication just before pressing the AMB switch.
a.
AMB: Pressing the AMB switch when ambient air temperature is indicated, the ambient air temperature indication will extinguish.
b.
Other switches: Pressing another switch when the ambient air temperature is indicated, the ambient air temperature indication will extinguish and the selected switch control will be performed.
INTAKE
Recirculation
Recirculation lamp will come on. "AUTO" lamp will go out.
Fix intake door at the recirculation position.
a.
REC.S/W : FRE./REC. mode control
b.
OFF S/W : Fixing at the current condition (manual selection is possible)
c.
AUTO : Auto control (fresh air, recirculation)
Fresh air
Fresh air lamp will come on. "AUTO" lamp will go out.
Fix intake door at the fresh air position.
Blower fan speed UP/DOWN
Blower fan speed, UP/DOWN control
Indicates fan operation on/off
a.
Pressing fan UP/DOWN during auto control, the speed will shift up/down based on the current fan level.
b.
Switching on a switch, except the fan switch at 'off' condition, the speed will rise steadily from LOW to the target speed. (Requires 6 seconds from LOW to HI).
c.
Shifting a step will take 0.7 seconds when pressing the switch once. Holding the switch, a shift will occur every 0.3 seconds and buzzer sounds for 0.1 second.
d.
Pressing UP switch at HI position or DOWN switch at LOW position, buzzer sound will occur 5 times at 0.4 second interval.
a.
AUTO: Auto control
b.
OFF : System off
c.
Fan speed control: Manual control of blower fan speed.
Output increment step by step
Fan speed levels and voltages