CIRCUIT INSPECTION
|
DTC |
B1348 |
DAB Short to ground |
|
B1354 |
PAB Short to ground |
|
B1363 |
DBPT Short to ground |
|
B1369 |
PBPT Short to ground |
|
B1380 |
DSAB Short to ground |
|
B1384 |
PSAB Short to
ground |
CIRCUIT DESCRIPTION
The squib
circuit consists of the SRSCM, clock spring, DAB, PAB, SAB, BPT, and
satellite sensors. It causes the SRS to deploy when the SRS deployment
conditions are satisfied. The above DTCs are recorded when a short to
ground is detected in the squib circuit.
|
DTC Detecting Condition |
Trouble Area |
| a. |
Short circuit in squib wire harness (to
ground) |
| c. |
Clock spring
malfunction |
|
|
WIRING DIAGRAM

INSPECTION PROCEDURE
| 1. |
Preparation (See step "1" on page
RT-33). |
| 2. |
Check DAB squib circuit.

[CHECK]
For the connector (on the clock spring side)
between the clock spring and the DAB, measure the resistance between
the DAB high and body ground.
Resistance : infinity

|
| 3. |
Check the PAB squib circuit.

[CHECK]
For the connector (on the SRSCM side) between
the SRSCM and the PAB, measure the resistance between the PAB high
and body ground.
Resistance : infinity

|
| 4. |
Check the PSAB and DSAB squib
circuit.

[CHECK]
For the connector (on the SRSCM side) between
the SRSCM and the SAB, measure the resistance between the SAB high
and body ground.
Resistance : infinity

|
| 5. |
Check the BPT squib circuit.

[CHECK]
For the connector (on the SRSCM side) between
the SRSCM and the BPT, measure the resistance between the BPT high
and body ground.
Resistance : infinity

|
| 6. |
Check the SRSCM.
[PREPARATION]
| a. |
Connect the connector to the
SRSCM. |
| b. |
Using a service wire, connect the DAB
high and the DAB low to the clock spring side connector
between the clock spring and the
DAB. |
| c. |
Using a service wire, connect the PAB
high and low on the SRSCM side of the connector between the
SRSCM and the PAB. |
| d. |
Connect the SAB and the BPT by the same
method. |
| e. |
Connect the negative (-) terminal cable
to the battery, and wait least 30
seconds. |

[CHECK]
| a. |
Turn the ignition switch to ON, and wait
at least 30 seconds. |
| b. |
Clear the malfunction code stored in the
memory with the Hi-Scan Pro. |
| c. |
Turn the ignition switch to LOCK, and
wait for 30 seconds. |
| d. |
Turn the ignition switch to ON, and wait
for 30 seconds. |
| e. |
Using Hi-Sacn Pro, check the
DTC.
There is no
DTC. |
[HINT]
Codes other than these ones may be output at
this time, but they are not relevant to this check.

|
| 7. |
Check the DAB squib.
[PREPARATION]
| a. |
Turn the ignition switch to
LOCK. |
| b. |
Disconnect the negative (-) terminal
cable from the battery, and wait for 30
seconds. |
| c. |
Connect the the DAB
connector. |
| d. |
Connect the negative (-) terminal cable
to the battery, and wait for 30
seconds. |

[CHECK]
| a. |
Turn the ignition switch to ON, and wait
for at least 30 seconds. |
| b. |
Clear the malfunction code stored in the
memory with the Hi-Scan Pro. |
| c. |
Turn the ignition switch to LOCK, and
wait for 30 seconds. |
| d. |
Turn the ignition switch to ON, and wait
for 30 seconds. |
| e. |
Using the Hi-scan, check the
DTC.
There is no
DTC. |
[HINT]
Codes other than these may be output at this
time, but they are not relevant to this procedure.

|
| 8. |
Check the PAB squib.
[PREPARATION]
| a. |
Turn the ignition switch to
LOCK. |
| b. |
Disconnect the negative (-) terminal
cable from the battery, and wait for 30
seconds. |
| c. |
Connect the the PAB
connector. |
| d. |
Connect the negative (-) terminal cable
from the battery, and wait for 30
seconds. |

[CHECK]
| a. |
Turn the ignition switch to ON, and wait
for at least 30 seconds. |
| b. |
Clear the malfunction code stored in the
memory with Hi-Scan Pro. |
| c. |
Turn the ignition switch to LOCK, and
wait for 30 seconds. |
| d. |
Turn the ignition switch to ON, and wait
for 30 seconds. |
| e. |
Using the Hi-Sacn Pro, check the
DTC.
There is no
DTC. |
[HINT]
Codes other than these may be output at this
time, but they are not relevant to this procedure.

|
| 9. |
Check the SAB squib.
[PREPARATION]
| a. |
Turn the ignition switch to
LOCK. |
| b. |
Disconnect the negative (-) terminal
cable from the battery, and wait for 30
seconds. |
| c. |
Connect the the SAB
connector. |
| d. |
Connect the negative (-) terminal cable
from the battery, and wait for 30
seconds. |

[CHECK]
| a. |
Turn the ignition switch to ON, and wait
for at least 30 seconds. |
| b. |
Clear the malfunction code stored in the
memory with the Hi-Scan Pro. |
| c. |
Turn the ignition switch to LOCK, and
wait for 30 seconds. |
| d. |
Turn the ignition switch ON, and wait
for 30 seconds. |
| e. |
Using the Hi-Sacn Pro, check the
DTC.
There is no
DTC. |
[HINT]
Codes other than these may be output at this
time, but they are not relevant to this procedure.

|
| 10. |
Check the BPT squib.
[PREPARATION]
| a. |
Turn the ignition swich to
LOCK. |
| b. |
Disconnect the negative (-) terminal
cable from the battery, and wait for 30
seconds. |
| c. |
Connect the BPT
connector. |
| d. |
Connect the negative (-) terminal cable
from the battery, and wait for 30
seconds. |

[CHECK]
| a. |
Turn the ignition switch to ON, and wait
for 30 seconds. |
| b. |
Clear the malfunction code stored in the
memory with the Hi-Scan Pro. |
| c. |
Turn the ignition switch to LOCK, and
wait for 30 seconds. |
| d. |
Turn the ignition switch to ON, and wait
for 30 seconds. |
| e. |
Using the Hi-Scan Pro, check the
DTC.
There is no
DTC. |
[HINT]
Codes other than these may be output at this
time, but they are not relevant to this procedure.

|
| 11. |
Check the clock spring circuit.
[PREPARAION]
Disconnect the connector between the SRSCM and
the clock spring.

[CHECK]
Measure the resistance between the DAB high on
the clock spring side of the connector between the clock spring and
the DAB and body ground.
Resistance : infinity

| |