While
operating the components, check whether the operations are normal with
timing chart.
ETACS FUNCTION
| 1. |
Variable intermittent wiper
Time specification
T1 : Max. 0.3 sec.
T2 : 0.6 ~ 0.8 sec. (Time of wiper motor 1
rotation)
T3 :Intermittent time
Min. 2.2 ± 0.2 sec. (at vr=0kΩ)
Max. 10 ± 1 sec. (at vr=50kΩ)

|
| 2. |
Washer
|
(1) |
Time specification
T1: 0.6 sec.
T2: 2.5 - 3.8
sec. |
|
(2) |
This function should be operated
preferentially even though the variable intermittent wiper is
operating. |

|
| 3. |
Wiper Mist
Time specification
T1: 0.2 - 0.6 sec.
T2: 0.7 ± 0.1 sec.

|
| 4. |
Rear window defogger
Time specification
T1: 60 msec
T2: 20 ± 1
min. |
| 5. |
Seat Belt Warning
Time specification
T1: 6 ± 1 sec.
T2: 0.45 ± 0.1 sec.
T3: 0.3 ± 0.1 sec.

|
| 6. |
Ignition key hole illumination
Time specification
T1: 10 ± 1 sec.
T2: 0 - 10 sec.

|
| 7. |
Delayed out room lamp
Time specification
T1: 5.5 ± 0.5 sec.
T2: 30 sec.

|
| 8. |
Door warning
Time specification
T1, T2: 0.45 ± 0.1 sec.

|
| 9. |
Ignition key reminder
Time specification
T1: 1 sec.
T2: 0.5 sec.
T3: Max. 0.5 sec.

|
| 10. |
Tail lamp auto cut

|
| 11. |
Power window timer
Time specification
T1: 30 ± 3 sec.

|
| 12. |
Central door lock/unlock
Time specification
T1: 0.5 ± 0.1 sec.

|
| 13. |
Trunk room lamp
Time specification
T1: 10 ± 1 min.

|
ANTI-THEFT FUNCTION
| 1. |
Arm Function
Time specification
T1: 0.6 sec.
T2: 1 ± 0.2 sec.

|
| 2. |
Disarm function
Time specification
T1, T2: 0.5 ± 0.1 sec.

|
| 3. |
Alarm function
|
(1) |
Time specification
T1: 27 ± 2 sec.
T2: 10 ± 1 sec.
T3: 0.5 ± 0.1
sec. |

|
(2) |
New alarm occurs while the alarm is
sounding.

|
|
(3) |
Disarmed with TX (Transmitter) while the
alarm is sounding.
Time specification
T1, T2, T3: 0.5 sec.

|
|
(4) |
TX (Transmitter) lock button pressed
when the door closed while the alarm is sounding.
Time specification
T1: 0.5 sec.
T2: 1.0 sec.

|
|
(5) |
TX (Transmitter) lock button pressed
when the door opened while the alarm is sounding.
Time specification
T1: 0.5 sec.
T2: 1.0 ± 0.2 sec.

|
|
(6) |
Disarmed after 30 sec when the ignition
switch is turned on while the alarm is sounding.

|
|
(7) |
After finished siren 3 times, start
inhibit is "ON" if door is opened regardless of door latch
lock state.

|
|
(8) |
Battery is disconnected during the alarm
state.

| |
| 4. |
Code saving method
|
(1) |
Remove the center facia
panel |
Don't disconnect the negative (-) battery
terminal.
|
(2) |
To store new codes:
| a. |
Activate the keyless
entry/receiver unit and change code saving switch of the
receiver unit from "OFF" to
"SET". |
| b. |
The secret codes from the
transmitter will be stored into the receiver unit when
the door lock button or unlock button is pressed on the
transmitter. |
| c. |
Save the 2nd transmitter codes in
the same manner |

|
|
(3) |
Return the code saving switch of the
receiver unit from "SET" to "OFF".

|
|
(4) |
Install the center facia