Home › Brake Systems › Anti-lock Brake System › Hydraulic and Electronic Control Unit

Anti-lock Brake System › Hydraulic and Electronic Control Unit: INSPECTION

INSPECTION AT HECU TERMINALS (ABS)

Connector terminal
Specification
Note
No.
Mark
Terminal name
4
IGN+
Power source via ignition switch terminal
Over voltage range : 16.5 ± 0.5V < V < 20V
Operating voltage range :
                  9.5 ± 0.5V
Low voltage threshold : 9.5 ± 0.5V
Low voltage range : 7.0 ± 0.5V < V < 9.5 ± 0.5V
System down range : 6.0 ± 0.5 < V < 7.0 ± 0.5V
Controller off range : V < 5.5 ± 0.5V
Max. current : I < 300mA
8
24
GND1
GND2
Ground terminal
Max. current (Total of 2 terminals) : I &< 60A
In ABS control
18
BRAKE
Brake lamp switch input terminal
Input voltage (Low) : -1.00 < V< 2.75V
Input voltage (High) : 5.00 < V< 16.00V
1
19
5
23
2
20
6
22
FL+
FR+
RL+
RR+
FL-
FR-
RL-
RR-
Wheel sensor input terminal
Min. sensor voltage : V> 150mV
Resistance : 1,385 ± 110Ω
Input range : 15 - 2000Hz
Inductance : 0.7H ± 50%
Permissible offset voltage range :
               2.15V < V< 3.5V
16
WLP
ABS and EBD warning lamp output terminal
Max. current : I < 200mA
Saturation voltage, at I = 200mA : V< 1.5V
7
Diag.
Diagnosis interface terminal
Input voltage : V< 0.3VV, V> 0.7VV
Output voltage : V< 0.2VV, V> 0.8VV
V: Ignition voltage
10
3
12
14
FL-out
FR-out
RL-out
RR-out
Wheel speed output terminal
Max. current : I < 10mA
External pull up resistance : above 10kΩ
(Open collector type)
9
Batt 1
Battery power
Source 1 terminal
(Valve power source)
Max. current (Inside control) : I <30A
Max. current (Outside control) : I v 20mA
Dark current : I < 0.3mA
25
Batt 2
Battery power
Source 2 terminal
(Motor power source)
In ABS control
Max. rush current : I < 100A (t < 100 msec)
Max. current : I < 30A (t > 100 msec)
At IGN off
Dark current : I < 0.3mA
t : The running time of motor