Home › Emissions Control System › Crankcase Emission Control System › Positive Crankcase Ventilation (PCV) Valve

Crankcase Emission Control System › Positive Crankcase Ventilation (PCV) Valve: REMOVAL

REMOVAL
1.
Disconnect the ventilation hose from the positive crankcase ventilation (PCV) valve. Remove the PCV valve from the rocker cover and reconnect it to the ventilation hose.
2.
Run the engine at idle and put a finger on the open end of the PCV valve and make sure that intake manifold vacuum can be felt.
The plunger inside the PCV valve will move back and forth.

3.
If vacuum is not felt, clean the PCV valve and ventilation hose in cleaning solvent, or replace if necessary.
INSPECTION
1.
Remove the PCV valve.
2.
Insert a thin stick into the PCV valve from the threaded side to check that the plunger moves.
3.
If the plunger does not move, the PCV valve is clogged. Clean it or replace.

INSTALLATION
Install the PCV valve and tighten to the specified torque.
PCV valve tightening torque: 8-12 Nm (80-120 kg.cm, 5.8-8.7 lb.ft)

PCV VALVE OPERATING
Intake manifold side (No vacuum)

Rocker cover side
Intake manifold side (High vacuum)

Rocker cover side
Engine condition
Not running
Engine condition
Idling or decelerating
PCV valve
Not operating
PCV valve
Fully operating
Vacuum passage
Restricted
Vacuum passage
Small
Intake manifold side (Moderate vacuum)

Rocker cover side
Intake manifold side (Low vacuum)

Rocker cover side
Engine condition
Normal operation
Engine condition
Accelerating and high load
PCV valve
Properly operating
PCV valve
Slightly operating
Vacuum passage
Large
Vacuum passage
Very large