This test
determines if the generator gives an output current that is equivalent to
the nominal output.
PREPARATION
| 1. |
Prior to the test, check the following items
and correct as necessary.
|
(1) |
Check if that the battery installed in
the vehicle is in good condition. For details,
seeBATTERY.
The battery that is used to test the
output current should be one that has been partially
discharged. With a fully charged battery, the test may not be
conducted correctly due to an insufficient
load. |
|
(2) |
Check the tension of the generator drive
belt. See
"COOLING". | |
| 2. |
Turn the ignition switch
toOFF. |
| 3. |
Disconnect the battery ground
cable. |
| 4. |
Disconnect the generator output wire from the
generator "B" terminal. |
| 5. |
Connect a DC ammeter (0 to 100A) in series
between the "B" terminal and the disconnected output wire. Be sure
to connect the (-) lead wire of the ammeter to the disconnected
output wire.
Tighten each connection securely, as a heavy
current will flow. Do not rely on
clips. |
| 6. |
Connect a voltmeter (0 to 20V) between the "B"
terminal and ground. Connect the (+) lead wire to the generator "B"
terminal and (-) lead wire to a good
ground. |
| 7. |
Attach an engine tachometer and connect the
battery ground cable. |
| 8. |
Leave the engine hood
open. |

TEST
| 1. |
Check to see that the voltmeter reads the same
value as the battery voltage. If the voltmeter reads 0V, an open
circuit in the wire between the generator "B" terminal and battery
(-) terminal, a blown fusible link or poor ground is
suspected. |
| 2. |
Start the engine and turn the headlights
on. |
| 3. |
Set the headlights to high beam and the heater
blower switch to HIGH, quickly increase the engine speed to 2,500
rpm and read the maximum output current value indicated by the
ammeter.
After the engine starts, the charging current
quickly drops. Therefore, the above operation must be done quickly
to read the maximum current value
correctly. |
RESULT
| 1. |
The ammeter reading must be higher than the
limit value. If it is lower but the generator output wire is in good
condition, remove the generator from the vehicle and test
it.
|
Limit
value |
|
52.5 A min. : 75A
generator |
|
63.0 A min. : 90A
generator |
| a. |
The nominal output current value is
shown on the nameplate affixed to the generator
body. |
| b. |
The output current value changes with
the electrical load and the temperature of the generator
itself. Therefore, the nominal output current may not be
obtained. In such case, keep the headlights on to discharge
the battery, or use the lights of another vehicle to increase
the electrical load.
The nominal output current may not be
obtained if the temperature of the generator itself or ambient
temperature is too high.
In such a case, reduce the temperature
before testing
again. | |
| 2. |
Upon completion of the output current test,
lower the engine speed to idle and turn off the ignition
switch. |
| 3. |
Disconnect the battery ground
cable. |
| 4. |
Remove the ammeter and voltmeter and the
engine tachometer. |
| 5. |
Connect the generator output wire to the
generator "B" terminal. |
| 6. |
Connect the battery ground
cable. |