Home › Engine Electrical System › Charging System › Generator (GEN)

Charging System › Generator (GEN): VOLTAGE DROP TEST

VOLTAGE DROP TEST OF GENERATOR OUTPUT WIRE
This test determines if the wiring between the generator "B" terminal and the battery (+) terminal is good by the voltage drop method.
PREPARATION
1.
Turn the ignition switch to "OFF."
To identify connection problems, be sure not to disturb either of the two terminals or their connections during this test.
2.
Connect a digital voltmeter between the generator "B" terminal and battery (+) terminal. Connect the (+) lead wire of the voltmeter to the "B" terminal and the (-) lead wire to the battery (+) terminal.
CONDITIONS FOR TESTING
With the engine running and headlamps, blower motor etc. ON, check the reading on the voltmeter.
RESULT
1.
The voltmeter should read a standard 0.3V.
2.
If the reading is above 0.3V, poor wiring should be suspected.
Check wiring from generator 'B' terminal through the fusible link to the battery (+) terminal.
Check for loose wiring or color change from an overheated harness. Correct and check again.
3.
On completion of the test, set the engine at idle.
Then turn off the headlamps, blower motor etc., and ignition.