| SWITCH
CONFIGURATION(MANUAL) |

| 1. |
BLOWER SWITCH
The blower switch controls the blowing level
of the air conditioning system by controlling blower motor speed.
The switch has an electrical circuit containing a resister that will
regulate blower motor input voltage to control the motor
speed. |
| 2. |
MODE SWITCH
The mode switch controls air conditioning
system discharge location. The switch contains an electrical circuit
to control an actuator that is connected to the mode door for
discharge control. |
| 3. |
TEMPERATURE SWITCH
The temperature switch controls the
temperature door position that will be used to regulate the air
conditioning system's discharge air temperature. The switch includes
a rack amp; pinion and a cable. |
| 4. |
INTAKE SWITCH
The intake switch controls the intake door
used to regulate the intake air flow of the air conditioning system.
The switch contains an electrical circuit used to control the
actuator that is connected to the intake
door. |
| 5. |
AIR CONDITIONING SWITCH
The air conditioning switch controls the
on/off position of the air conditioning system compressor. The
switch contains an electrical circuit that will switch on/off the
power supply to the relay that is connected to the
compressor. |
| 6. |
REAR DEFOGGER SWITCH
The rear defogger switch is used to defog the
rear glass. Switching the switch on, ETACS will output a signal to
operate the rear glass heat wire. |
| a. |
When Mix or DEF mode is selected with the
blower motor on. |
| 1) |
Air conditioning system is switched ON and air
intake control is switched to fresh air
mode. |
| 1) |
A/C can not be turned
OFF. |
| 1) |
A/C indicator will not be turned ON at MIX or
DEF mode even through A/C is operating if A/C was not used before
selecting MIX or DEF mode. |
| b. |
When blower is turned OFF, air intake control
is always set to fresh air mode.
However, fresh air or recirculation mode can
be selected. |
CONTROL UNIT PIN CONFIGURATION (MANUAL)

|
Connector |
Pin No. |
Name |
Connector |
Pin No. |
Name |
|
Blower switch
|
1 |
MIDDLE HIGH |
Main connector
(A/CON control module)
|
1 |
SWITCH |
|
2 |
COMMON |
2 |
GROUND |
|
3 |
GROUND |
3 |
B+ (Blower relay"ON") |
|
4 |
HIGH |
4 |
ON INPUT |
|
5 |
MIDDLE LOW |
5 |
ILLUMINATION (-) |
|
6 |
LOW |
6 |
ILLUMINATION (+) |
|
Main switch
|
1 |
HOT at ON |
7 |
RECIRC |
|
2 |
GROUND |
8 |
FRE |
|
3 |
MODE ACT. (VENT) |
9 |
- |
|
4 |
MODE ACT. (DEF) |
10 |
- |
|
5 |
VCC |
11 |
- |
|
6 |
F/B |
12 |
- |
|
7 |
F/B GROUND |
13 |
MEMORY POWER |
|
8 |
DEF LOGIC |
14 |
DEFOG. LOGIC |
|
Temp. switch
|
1 |
ON INPUT |
15 |
DEFOG. SWITCH |
|
2 |
GROUND |
16 |
DEFOG. SWITCH |
|
3 |
TEMP ACT. (WARM) |
|
|
4 |
TEMP ACT. (COOL) |
|
5 |
VCC |
|
6 |
F/B |
|
7 |
GROUND |
|
8 |
- |