Home › Restraints › Troubleshooting

Troubleshooting: DTC (SQUIB CIRCUIT SHORT TO GND)

CIRCUIT INSPECTION
DTC
B1348
DAB Short to ground
B1354
PAB Short to ground
B1363
DBPT Short to ground
B1369
PBPT Short to ground
B1380
DSAB Short to ground
B1384
PSAB Short to ground

CIRCUIT DESCRIPTION
The squib circuit consists of the SRSCM, clock spring, DAB, PAB, SAB, BPT, and satellite sensors. It causes the SRS to deploy when the SRS deployment conditions are satisfied. The above DTCs are recorded when a short to ground is detected in the squib circuit.
DTC Detecting Condition
Trouble Area
a.
Short circuit in squib wire harness (to ground)
b.
Squib malfunction
c.
Clock spring malfunction
d.
SRSCM malfunction
a.
DAB squib
b.
PAB squib
c.
DSAB squib
d.
PSAB squib
e.
BPT squib
f.
Clock spring
g.
SRSCM
h.
Wire harness

WIRING DIAGRAM

INSPECTION PROCEDURE
1.
Preparation (See step "1" on page RT-33).
2.
Check DAB squib circuit.

[CHECK]
For the connector (on the clock spring side) between the clock spring and the DAB, measure the resistance between the DAB high and body ground.
Resistance : ∞

3.
Check the PAB squib circuit.

[CHECK]
For the connector (on the SRSCM side) between the SRSCM and the PAB, measure the resistance between the PAB high and body ground.
Resistance : ∞

4.
Check the PSAB and DSAB squib circuit.

[CHECK]
For the connector (on the SRSCM side) between the SRSCM and the SAB, measure the resistance between the SAB high and body ground.
Resistance : ∞

5.
Check the BPT squib circuit.

[CHECK]
For the connector (on the SRSCM side) between the SRSCM and the BPT, measure the resistance between the BPT high and body ground.
Resistance : ∞

6.
Check the SRSCM.
[PREPARATION]
a.
Connect the connector to the SRSCM.
b.
Using a service wire, connect the DAB high and the DAB low to the clock spring side connector between the clock spring and the DAB.
c.
Using a service wire, connect the PAB high and low on the SRSCM side of the connector between the SRSCM and the PAB.
d.
Connect the SAB and the BPT by the same method.
e.
Connect the negative (-) terminal cable to the battery, and wait least 30 seconds.

[CHECK]
a.
Turn the ignition switch to ON, and wait at least 30 seconds.
b.
Clear the malfunction code stored in the memory with the Hi-Scan Pro.
c.
Turn the ignition switch to LOCK, and wait for 30 seconds.
d.
Turn the ignition switch to ON, and wait for 30 seconds.
e.
Using Hi-Sacn Pro, check the DTC.
There is no DTC.
[HINT]
Codes other than these ones may be output at this time, but they are not relevant to this check.

7.
Check the DAB squib.
[PREPARATION]
a.
Turn the ignition switch to LOCK.
b.
Disconnect the negative (-) terminal cable from the battery, and wait for 30 seconds.
c.
Connect the the DAB connector.
d.
Connect the negative (-) terminal cable to the battery, and wait for 30 seconds.

[CHECK]
a.
Turn the ignition switch to ON, and wait for at least 30 seconds.
b.
Clear the malfunction code stored in the memory with the Hi-Scan Pro.
c.
Turn the ignition switch to LOCK, and wait for 30 seconds.
d.
Turn the ignition switch to ON, and wait for 30 seconds.
e.
Using the Hi-scan, check the DTC.
There is no DTC.
[HINT]
Codes other than these may be output at this time, but they are not relevant to this procedure.

8.
Check the PAB squib.
[PREPARATION]
a.
Turn the ignition switch to LOCK.
b.
Disconnect the negative (-) terminal cable from the battery, and wait for 30 seconds.
c.
Connect the the PAB connector.
d.
Connect the negative (-) terminal cable from the battery, and wait for 30 seconds.

[CHECK]
a.
Turn the ignition switch to ON, and wait for at least 30 seconds.
b.
Clear the malfunction code stored in the memory with Hi-Scan Pro.
c.
Turn the ignition switch to LOCK, and wait for 30 seconds.
d.
Turn the ignition switch to ON, and wait for 30 seconds.
e.
Using the Hi-Sacn Pro, check the DTC.
There is no DTC.
[HINT]
Codes other than these may be output at this time, but they are not relevant to this procedure.

9.
Check the SAB squib.
[PREPARATION]
a.
Turn the ignition switch to LOCK.
b.
Disconnect the negative (-) terminal cable from the battery, and wait for 30 seconds.
c.
Connect the the SAB connector.
d.
Connect the negative (-) terminal cable from the battery, and wait for 30 seconds.

[CHECK]
a.
Turn the ignition switch to ON, and wait for at least 30 seconds.
b.
Clear the malfunction code stored in the memory with the Hi-Scan Pro.
c.
Turn the ignition switch to LOCK, and wait for 30 seconds.
d.
Turn the ignition switch to ON, and wait for 30 seconds.
e.
Using the Hi-Sacn Pro, check the DTC.
There is no DTC.
[HINT]
Codes other than these may be output at this time, but they are not relevant to this procedure.

10.
Check the BPT squib.
[PREPARATION]
a.
Turn the ignition swich to LOCK.
b.
Disconnect the negative (-) terminal cable from the battery, and wait for 30 seconds.
c.
Connect the BPT connector.
d.
Connect the negative (-) terminal cable from the battery, and wait for 30 seconds.

[CHECK]
a.
Turn the ignition switch to ON, and wait for 30 seconds.
b.
Clear the malfunction code stored in the memory with the Hi-Scan Pro.
c.
Turn the ignition switch to LOCK, and wait for 30 seconds.
d.
Turn the ignition switch to ON, and wait for 30 seconds.
e.
Using the Hi-Scan Pro, check the DTC.
There is no DTC.
[HINT]
Codes other than these may be output at this time, but they are not relevant to this procedure.

11.
Check the clock spring circuit.
[PREPARATION]
Disconnect the connector between the SRSCM and the clock spring.

[CHECK]
Measure the resistance between the DAB high on the clock spring side of the connector between the clock spring and the DAB and body ground.
Resistance : ∞