P0736
|
Reverse gear
asynchronous error
| -
|
Input shaft speed - (Output shaft speed
x reverse gear ratio) ≥
200rpm |
| -
|
ATF temperature ≥
-23°C |
| -
|
After 2sec is passed from shift of shift
to reverse gear |
| -
|
Output shaft speed ≥
350rpm |
| -
|
Input shaft speed ≠
0rpm |
| -
|
Transaxle range switch is
normal |
| -
|
After 2sec is passed from IGN
ON | |
| -
|
Malfunction of the input shaft speed
sensor |
| -
|
Malfunction of the output shaft speed
sensor |
| -
|
Malfunction of the UD clutch
retainer |
| -
|
Malfunction of the transfer drive gear
or driven gear |
| -
|
Malfunction of the LR brake
system |
| -
|
Malfunction of the reverse clutch