Home › Restraint › Troubleshooting

B1348 1st stage Driver airbag (DAB), Short to ground

INSPECTION PROCEDURE FOR DIAGNOSTIC TROUBLE CODES
DTC
B1348 DAB 1st stage short to ground
B1483 DAB 2nd stage short to ground

DESCRITION
The squib circuit consists of the SRSCM, clock spring and DAB.
It causes the SRS to deploy when the SRS deployment conditions are satisfied. The above DTC is recorded when a short to ground is detected in the squib circuit.

DTC DETECTING CONDITION
Condition
Probable cause
•
Short circuit is squib wire harness (to ground)
•
Squib malfunction
•
Clock spring malfunction
•
SRSCM malfunction
•
DAB squib
•
Clock spring
•
SRSCM
•
Wire harness

INSPECTION PROCEDURES