BURGLAR ALARM SYSTEM
The system is set off
when any of these things occur :
| • |
A door is unlocked without using the
transmitter. |
| • |
The trunk lid is opened without using the
key. |
| • |
The engine starter circuit and battery circuit
are bypassed by breaking the ignition
switch. |
KEYLESS ENTRY SYSTEM
| 1. |
ARM
FUNCTION
Pressing the remote key lock button will
result in a 0.5-second pulse issued to lock all doors.
Pressing the remote keypad unlock button once
will result in a 0.5-second unlock pulse issued to unlock all
doors.
As part of the arming sequence, the alarm
first enters a pre-armed state before falling into the armed state.
During this pre-armed state, the alarm triggers are ignored.
Pre-armed state can be reached from the alarmed state, the start
inhibit state or the disarmed state. Pre-Arming of the alarm can be
achieved by a press of the lock button on the remote
key.
In the pre-armed state the visible and audible
warnings are disabled.
This system enters the armed state if it is in
the pre-armed state and,after 0.6 sec, check actuator lock and each
door, hood and trunk close,and no door warning switch (no key in
ignition).
On entering the arm state, a single flash of
the hazard lamps is given,period of cycle 2 second, duty rate
50%.
If transmitter(TX) lock signal is received
when a door, trunk or hood is open,then lock output is given but a
flash of hazard is not given.
After the armed state is entered, if a lock
signal is received then a single flash of the hazard lamps is given,
period of cycle 2 second, duty rate 50%.
The armed state cannot be reached by locking
the car with the keys.

Time specification
T1 : 0.5 ± 0.1 sec.
T2 : Max. 2 sec.
T3 : 1.0 ± 0.2
sec. |
| 2. |
DISARM
FUNCTION
Disarming can be performed while the alarm is
armed, or alarming, or after alarming. The alarm can be disarmed by
the following methods :
| A. |
Pressing the unlock button on the
transmitter(TX) key. The hazard lamps shall be flashed twice
for 1sec period (of cycle), 50% duty
rate. |
| B. |
If door warning switch is on, IGN1 and
IGN2 are on in arm state,then arm state should be immediately
cancelled. This means that the driver is inside the vehicle
before pushing TX lock, so system should not
arm. |
In the disarm state the visible and audible
warnings are disabled and start is enabled.
In the disarm state, if TX key unlock command
is received, then the hazard lamps shall flashed twice for a period
of cycle 1 sec, 50% duty rate.

Time specification
T1, T2 : 0.5 ± 0.1
sec. |
| 3. |
ALARM
FUNCTION
Once armed, should any door, hood or the trunk
be opened, then.
| A. |
Starter relay drive output is disabled,
so starting is inhibited. |
| B. |
Audible (siren) and visual (hazard lamp)
warnings are issued, for three cycles, each cycle 27±2 sec.
duration on, 10±1 sec. off. The siren warning is continuously
occurring during the on period. The hazard lamps operate with
1 sec period, 50 % duty rate during the on
period. |
The alarm is given in the case where a door is
opened with a key.
After this time, the system maintains the
start inhibit state, where no audible and visual warnings are issued
but engine starting is not possible.

Time specification
T1 : 27 ± 2 sec.
T2 : 10 ± 1sec.
T3 : 0.5 ± 0.1
sec. |
| 4. |
OPERATION DURING
ALARM CONDITIONS
| (1) |
Cancelling audible alarm with the remote
transmitter.
CASE 1 : Door
closed
During or after alarming and then
closing all doors and a transmitter (TX) lock signal is
received Then
| A. |
The lock command is executed with
0.5 sec. ON |
| B. |
Siren and start inhibition are
OFF |
| C. |
Hazard lamp is flashed one time
(period : 2 sec., duty: 50%, within2
sec.) |
| D. |
The state goes to arming mode
(after a lock state
check) |
| E. |
The starter is
enabled

|
Time specification
T1 : 0.5 sec.
T2 : 1.0 ± 0.2 sec.
CASE 2 : Door
Open
During or after alarming, with a door
open and a TX lock signal is received Then
| A. |
The lock command is executed with
0.5 sec. ON |
| B. |
Siren is disabled and start is
enabled after confirmation of actuator
lock |
At this time, when the door is
closed,
| A. |
Hazard lamp is flashed one time
(period : 2 sec., duty
50%) |
| B. |
The state goes to arming
mode

|
Time specification
T1 : 0.5 sec.
T2 : 1.0 ± 0.2
sec. |
| (2) |
New alarm conditions
Second alarm condition during
alarming.
When another alarm occurs during
alarming, the starting is disabled,and the alarm continues to
sound for the remained time of warning signal.The alarm
continues to sound after the second alarm condition is
removed.
New alarm condition occurs after
alarming (with all entrances closed)
If any entrance is opened again
then
| A. |
The siren is ON 3
times |
| C. |
Hazard lamps flash during the ON
time of siren |
New alarm condition occur after alarming
(with any entrance open).
If another entrance is opened, the ETACS
module keeps start disabled and there is no siren
output.

|
| (3) |
Key operation during alarm
After the alarm state or start inhibit
state are entered, if door warning switch on (key in ignition)
&IGN 2 ON, if IGN 2 state is changed to OFF within 30sec.,
remain in alarm state. |
| (4) |
Disarming using the key
During alarming, in case that door
warning switch (key in) is ON andthen IGN1 and IGN2 are both
ON for 30 sec continuously, the alarm is cancelled,and the
system enters the disarm state.
After alarming, in case that door
warning switch (key in) is ON and then IGN1 and IGN2 are both
ON for 30 sec continuously, the alarm is cancelled,and the
system enters the disarm state.

| |
| 5. |
ALARM STATE IN POWER
DOWN
If the battery is disconnected to the ETACS
module in the following states :
Upon restoring the battery, the alarm state
shall be entered and the alarm cycle shall restart (timer reset to
0).

|
| 6. |
ALARM HOLD
MODE
| (1) |
In case of opening the trunk by trunk
unlock switch during arm state, the alarming is
hold.
When received transmitter (TX) trunk
signal in arm state, trunk open by output trunk lid open relay
signal for 500ms and then holding alarm.
But the door and hood is still in the
arm state. |
| (2) |
Trunk is going to the arm state just
case trunk is still closed for 2 sec.

T1 : Max. 0.2 sec., T2 : 2
sec. | | |