POWER RELAY TEST (TYPE A)
Check for
continuity between the terminals.
| 1. |
There should be continuity between the No.1
and No.2 terminals when power and ground are connected to the No.4
and No.3 terminals. |
| 2. |
There should be no continuity between the No.1
and No.2 terminals when power is disconnected.


|
POWER RELAY TEST (TYPE B)
Check for
continuity between the terminals.
| 1. |
There should be continuity between the No.1
and No.2 terminals when power and ground are connected to the No.5
and No.3 terminals. |
| 2. |
There should be continuity between the No.1
and No.4 terminals when power is disconnected.


|
POWER RELAY TEST (TYPE C)
Check for
continuity between the terminals.
| 1. |
There should be continuity between the No.1
and No.4 terminals when power and ground are connected to the No.3
and No.2 terminals. |
| 2. |
There should be no continuity between the No.1
and No.4 terminals when power is disconnected.


|
POWER RELAY TEST (TYPE D)
Check for
continuity between the terminals.
| 1. |
There should be continuity between the No.1
and No.5 terminals when power and ground are connected to the No.4
and No.2 terminals. |
| 2. |
There should be continuity between the No.3
and No.5 terminals when power is disconnected.


|