Home › Heating,Ventilation, Air Condioning › General Information

General Information: Description and Operation

AIR FLOW DESCRIPTION

MANUAL AIR CONDITION CONTROL PANEL

AUTOMATIC AIR CONDITION CONTROL PANEL

COMPONENT SCHEMATIC

Item
Description
Item
Description
1
Recirculating air port
8
Defrost airflow door
2
Outside air port
9
Panel airflow door
3
Defrost air vent
10
Floor airflow door
4
Panel air vent
11
Air filter
5
Floor air vent
12
Blower unit
6
Air inlet blend door
13
Evaporator core
7
Air temperature control door
14
Heater core

SYSTEM AIR FLOW DESCRIPTION
MAX A/C

-
Air inlet blend door : Recirc
-
Air temperature control door : Max. cold
-
Defrost airflow door : Close
-
Panel airflow door : Open
-
Floor airflow door : Close
-
A/C compressor : ON
-
Blower motor : ON
No override allowed to A/C OFF and recirc.
(Manual A/C only)
A/C

-
Air inlet blend door : Fresh
-
Air temperature control door : Enable to select
-
Defrost airflow door : Enable to select
-
Panel airflow door : Enable to select
-
Floor airflow door : Enable to select
-
A/C compressor : ON
-
Blower motor : ON
PANEL

-
Air inlet blend door : Fresh
-
Air temperature control door : Enable to select
-
Defrost airflow door : Close
-
Panel airflow door : Open
-
Floor airflow door : Close
-
A/C compressor : Enable to select
-
Blower motor : ON
OFF

-
Air inlet blend door : Recirc
-
Air temperature control door : Enable to select
-
Defrost airflow door : Open
-
Panel airflow door : Close
-
Floor airflow door : Close
-
A/C compressor : OFF
-
Blower motor : OFF
PANEL/FLOOR

-
Air inlet blend door : Fresh
-
Air temperature control door : Enable to select
-
Defrost airflow door : Close
-
Panel airflow door : Open
-
Floor airflow door : Open
-
A/C compressor : Enable to select
-
Blower motor : ON
FLOOR

-
Air inlet blend door : Fresh
-
Air temperature control door : Enable to select
-
Defrost airflow door : Close
-
Panel airflow door : Close
-
Floor airflow door : Open
-
A/C compressor : Enable to select
-
Blower motor : ON
FLOOR/DEFROST

-
Air inlet blend door : Fresh
-
Air temperature control door : Enable to select
-
Defrost airflow door : Open
-
Panel airflow door : Close
-
Floor airflow door : Open
-
A/C compressor : ON
-
Blower motor : ON
The A/C compressor shall be always ON at FLOOR/DEFROST mode.
but, A/C indicator can be turned ON/OFF.
DEFROST

-
Air inlet blend door : Fresh
-
Air temperature control door : Enable to select
-
Defrost airflow door : Open
-
Panel airflow door : Close
-
Floor airflow door : Close
-
A/C compressor : ON
-
Blower motor : ON
The A/C compressor shall be always ON at DEFROST mode.
but, A/C indicator can be turned ON/OFF.