| MANUAL AIR CONDITION CONTROL
PANEL |

| AUTOMATIC AIR CONDITION CONTROL
PANEL |

COMPONENT SCHEMATIC


Item
|
Description
|
Item
|
Description
|
1
|
Recirculating
air port
|
8
|
Defrost
airflow door
|
2
|
Outside air
port
|
9
|
Panel airflow
door
|
3
|
Defrost air
vent
|
10
|
Floor airflow
door
|
4
|
Panel air
vent
|
11
|
Air
filter
|
5
|
Floor air
vent
|
12
|
Blower
unit
|
6
|
Air inlet
blend door
|
13
|
Evaporator
core
|
7
|
Air
temperature control door
|
14
|
Heater
core
|
SYSTEM AIR FLOW DESCRIPTION
MAX A/C

| - |
Air inlet blend door :
Recirc |
| - |
Air temperature control door : Max.
cold |
| - |
Defrost airflow door :
Close |
| - |
Panel airflow door :
Open |
| - |
Floor airflow door :
Close |
| - |
Blower motor : ON
|
No override allowed to A/C OFF and
recirc.
(Manual A/C
only) | |
A/C

| - |
Air inlet blend door :
Fresh |
| - |
Air temperature control door : Enable to
select |
| - |
Defrost airflow door : Enable to
select |
| - |
Panel airflow door : Enable to
select |
| - |
Floor airflow door : Enable to
select |
PANEL

| - |
Air inlet blend door :
Fresh |
| - |
Air temperature control door : Enable to
select |
| - |
Defrost airflow door :
Close |
| - |
Panel airflow door :
Open |
| - |
Floor airflow door :
Close |
| - |
A/C compressor : Enable to
select |
OFF

| - |
Air inlet blend door :
Recirc |
| - |
Air temperature control door : Enable to
select |
| - |
Defrost airflow door :
Open |
| - |
Panel airflow door :
Close |
| - |
Floor airflow door :
Close |
PANEL/FLOOR

| - |
Air inlet blend door :
Fresh |
| - |
Air temperature control door : Enable to
select |
| - |
Defrost airflow door :
Close |
| - |
Panel airflow door :
Open |
| - |
Floor airflow door :
Open |
| - |
A/C compressor : Enable to
select |
FLOOR

| - |
Air inlet blend door :
Fresh |
| - |
Air temperature control door : Enable to
select |
| - |
Defrost airflow door :
Close |
| - |
Panel airflow door :
Close |
| - |
Floor airflow door :
Open |
| - |
A/C compressor : Enable to
select |
FLOOR/DEFROST

| - |
Air inlet blend door :
Fresh |
| - |
Air temperature control door : Enable to
select |
| - |
Defrost airflow door :
Open |
| - |
Panel airflow door :
Close |
| - |
Floor airflow door :
Open |
| - |
Blower motor : ON
|
The A/C compressor shall be always ON at
FLOOR/DEFROST mode.
but, A/C indicator can be turned
ON/OFF. | |
DEFROST

| - |
Air inlet blend door :
Fresh |
| - |
Air temperature control door : Enable to
select |
| - |
Defrost airflow door :
Open |
| - |
Panel airflow door :
Close |
| - |
Floor airflow door :
Close |
| - |
Blower motor : ON
|
The A/C compressor shall be always ON at
DEFROST mode.
but, A/C indicator can be turned
ON/OFF. | |