Home
›
Heating,Ventilation, Air Condioning
›
Air conditioning System
›
Refrigerant line
Air conditioning System › Refrigerant line: Repair procedures
REPLACEMENT
1.
Discharge refrigerant from refrigeration system.
2.
Replace faulty tube or hose.
Cap the open fittings immediately to keep moisture or dirt out of the system.
3.
Tighten joint of bolt or nut to specified torque
Connections should no be torqued tighter than the specified torqued.
4.
Evacuate air in refrigeration system and charge system with refrigerant.
Specified amount : 680 ± 25g
5.
Inspect for leakage of refrigerant.
Using a gas leak detector, check for leakage of refrigerant.
6.
Inspect A/C operation.
Part tightened
N·m
kgf·cm
lbf·ft
Condenser x Discharge hose
9 ~ 11
90 ~ 110
6.6 ~ 8.1
Condenser x Liquid tube
9 ~ 11
90 ~ 110
6.6 ~ 8.1
Compressor x Discharge hose
20 ~ 25
200 ~ 250
14.8 ~ 18.4
Compressor x Suction hose
20 ~ 25
200 ~ 250
14.8 ~ 18.4
Expansion valve x Evaporator
9 ~ 11
90 ~ 110
6.6 ~ 8.1