REPLACEMENT
1.
Disconnect the 7P connector (A) from the inlet actuator (B). Remove the self-tapping screws and the inlet actuator from the blower unit.
2.
Install in the reverse order of removal. After installation, make sure the inlet actuator runs smoothly.