| 1. |
Disconnect the negative (-) battery
terminal. |
| 2. |
Remove the 2 screws(A) holding the instrument
facia panel.

|
| 3. |
Remove the ash tray then remove the 2
screws(A) holding the instrument facia panel.

|
| 4. |
Remove the instrument facia
panel.
Remove the air conditioner switch panel(A)
after removing 4 screws.

|
| 5. |
Remove the ETACS module (A) after removing 2
bolts.

|
| 6. |
Installation is the reverse of
removal. |
| 1. |
VARIABLE INTERMITTENT WIPER

Time specification
T1 : Max. 0.3sec.
T2 : 0.6~0.8 sec. (Time of wiper motor 1
rotation)
T3 : 2.2±0.2 sec. (VR=0kΩ)~10.0±1 sec.
(VR=50kΩ) |
| 2. |
WASHER

| A. |
Time specification
T1 : 0.3 sec.
T2 : 0.2 sec. or more
T3 : 2.5~3.8
sec. |
| B. |
Time specification
T1 : 0.3 sec.
T2 : 0.2 sec. or less
T3 : 0
sec. |
| C. |
This function should be operated
preferentially even though the variable intermittent wiper is
operating. | |
| 3. |
DEFOGGER TIMER (Including Outside Mirror
Demister)
| (1) |
After ALT "L" ON, if the defogger is
switched ON, the defogger output is ON for 20 minutes
duration. |
| (2) |
If the defogger switch is pressed again,
or if the ignition is switched OFF during this time, the
defogger output is OFF. |

T1 : 20 ±
1min. |
| 4. |
SEAT BELT WARNING TIMER
| (1) |
Since the ignition is switched ON, the
seat belt warning indicator is illuminated (with period : 0.6
sec., duty rate : 50%) until the seat belt switch is ON and
the chime bell is sounded (with period : 0.9 sec., duty rate :
50%) for 6 seconds. |
| (2) |
If the ignition is swithced off during
the indicator and the chime bell output, the indicator and the
chime bell are switched OFF.
If the seat belt is sensed as fastened
during the indicator and the chime bell output, the chime bell
and seat belt warning indicator are switched OFF
immediately. |
| (3) |
When the ignition is already switched
ON, if the seat belt is removed, the warning indicator is
illuminated until the seat belt is fastened and the chime bell
is output for 6 seconds.

|
T1 : 6±1 sec., T2 : 0.45 ± 0.1 sec., T3 : 0.3
± 0.1 sec. |
| 5. |
DECAYED ROOM LAMP & KEYLESS UNLOCK
TIMER
| (1) |
When the first door (driver's or assist)
is opened, the room lamp shall brighten. When the last door is
closed, the room lamp will drop to 75% intensity, then fade
out over 5-6 seconds. |
| (2) |
If the door switch is ON for less than
0.1 sec., then no illumination
occurs. |
| (3) |
The fade resolution is over 32
steps. |
| (4) |
The room lamp must not flicker during
fade operation, if the ignition is switched
ON. |
| (5) |
With keyless UNLOCK, when the door is
closed, the room lamp is turned ON, then OFF after about 30
seconds. While the room lamp is ON due to keyless UNLOCK, if
another UNLOCK is received, the room lamp is again ON for 30
seconds.
While the room lamp is ON, If the door
is opened, the lamp is continued to ON. If the door is closed,
the lamp follows as the above step 1.
If keyless LOCK (ARM state) is received
during fade out, the room lamp is switched off
immediately.

T1 : 5.5 ± 0.5 sec., T2 : 30 ± 3
sec. | |
| 6. |
CENTRAL DOOR LOCK/UNLOCK
| (1) |
If the assist door is switched LOCK to
UNLOCK or UNLOCK to LOCK, the all doors' lock and unlock
outputs will follow. |
| (2) |
If the driver's door key lock switch is
OFF to ON, the all doors' lock output is ON for 0.5
second. |
| (3) |
If the transmitter's lock signal is
received, the all doors' lock output is ON for 0.5
second. |
| (4) |
If the driver's door key unlock switch
is OFF to ON, the driver's door unlock output is ON and then
if the driver's door key unlock switch is ON within 4 seconds,
the all doors' unlock output is ON for 0.5
second. |
| (5) |
If the transmitter's unlock signal is
received, the driver's door unlock output is ON and then if
the transmitter's another unlock signal is received, within 4
seconds, the all doors' unlock output is ON for 0.5
second.

T1 : within 4 ± 1 sec.
T2 : 0.5 ± 0.1
sec | |
| 7. |
IGNITION KEY REMINDER

T1,T3 : 0.5 sec., T2 : 1 sec., T4 : Max.0.5
sec. |
| 8. |
POWER WINDOW TIMER
| (1) |
When the ignition is switched ON, the
power window relay output is turned
ON. |
| (2) |
When the ignition is switched OFF, the
power window output is maintained ON for 30 seconds and then
turned OFF. |
| (3) |
With the state of step 2, if the
driver's door or assist door is opened, the output shall be
turned OFF immediately.

T1 : 30 ± 3
sec. | |
| 9. |
DOOR OPEN WARNING
| (1) |
If the key is in the ignition key
cylinder and the driver's door is opened, the chime bell
sounds continually (period:0.9 sec. Duty
rate:50%). |
| (2) |
If the door is closed or the key is
removed, the chime stops immediately.

T1,T2 : 0.45 ± 0.1
sec. | |
| 10. |
TAIL LAMP AUTO CUT
| (1) |
When the tail lamp is switched ON, if
the ignition is switched OFF and the driver's door is opened,
the tail lamp should be automatically
OFF. |
| (2) |
With the ignition switched ON, if the
driver's door is opened and the ignition is switched OFF, the
tail lamp should be automatically
OFF. |
| (3) |
When the tail lamp is cut automatically,
if the tail lamp switch is turned OFF and ON, the tail lamp is
illuminated and auto cut function is cancelled.

| |
| 11. |
CRASH DOOR UNLOCK
| (1) |
With the ignition turned ON, if the air
bag is deployed, a crash signal is received and send an UNLOCK
output to all doors UNLOCK. |
| (2) |
After UNLOCK output, when LOCK is set,
UNLOCK pulse is output for 5 second period again.

T1 : 200 msec.
T2 : 40 msec.
T3 :
5±0.5sec. | |
| 12. |
IGNITION KEY HOLE ILLUMINATION
| (1) |
Ignition key hole illumination is turned
ON when driver door or assist door is opened with ignition
switch OFF. |
| (2) |
Delaying "ON" state of ignition key hole
illumination for 10 seconds when the door is closed in case of
(1) state. |
| (3) |
Ignition key hole illumination is turned
off if the ignition switch turned ON in case of (1), (2)
state. |
| (4) |
Ignition key hole illumination is turned
off if arm state is entered in case of (1), (2)
state.

T1 : 10±1 sec.
T2 : 0~10
sec. | |
| 13. |
PANIC ALARM
| (1) |
If transmitter's panic signal is
received, the panic alarm output is ON for 30
seconds. |
| (2) |
If the transmitter's panic signal is
received during panic alarming, the panic alarm output will
turn OFF.

| | |