1. OVERVIEW
The California Air
Resources Board (CARB) began regulation of On Board Diagnostics (OBD) for
vehicles sold in california beginning with the 1988 model year. The first
phase, OBD-I, required monitoring of the fuel metering system, Exhust Gas
Recirculation (EGR) system and additional emission related components. The
Malfunction Indicator Lamp (MIL) was required to light and alert the
driver of the fault and the need for repair of the emission control
system. Associated with the MIL was a fault code or Diagnostic Trouble
Code (DTC) idenfying the specific area of the fault.
The OBD system was
proposed by CARB to improve air quality by identifying vehicle exceeding
emission standards. Passage of the Federal Clean Air Act Amendments in
1990 has also prompted the Environmental Protection Agency (EPA) to
develop On Board Diagnostic requirements. CARB OBD-II regulations will be
followed until 1999 when the federal regulations will be
used.
The OBD-II system meets
government regulations by monitoring the emission control system. When a
system or component exceeds emission threshold or a component operates
outside tolerance, a DTC will be stored and the MIL
illuminated.
The diagnostic executive
is computer program in the Engine Control Module (ECM) that coordinates
the OBD-II self-monitoring system. This program controls all the monitors
and interactions, DTC and MIL operation, freeeze frame data and scan tool
interface.
Freeze frame data
describes stored engine conditions, such as state of the engine, state of
fuel control, spark, RPM, load and warm status at the point the first
fault is detected. Previously stored conditions will be replace only if a
fuel or misfire fault is detected. This data is accessible with the scan
tool to assist in repairing the vehicle.
The center of the OBD-II
system is a microprocessor called the Engine Control Module (ECM) which
has two connector (MT:81 pin, AT:121 pin).
The ECM receives input
from sensors and other electronic components (switches, relays, and
others) based on information received and programmed into its memory (keep
alive random acess memory, and others), the ECM generates output signals
to control various relays, solenoids and actuators.
Break
When a freeze frame
event is triggered by an emission related DTC, the ECM stores various
vehicle information as it existed the moment the fault ocurred. The DTC
number along with the engine data can be useful in aiding a technician in
locating the cause of the fault. Once the data from the 1st driving cycle
DTC ocurrence is stored in the freeze frame memory, it will remain there
even when the fault ocurrs again (2nd driving cycle) and the MIL is
illuminated.
Break
The cooling system
monitoring is a self-test strategy within the ECM that monitors ECTS
(Engine Coolant Temperature Sensor) and thermostat about circuit
continuity, output range, rationality faults.
OBD-II regulations
require monitoring of the upstream Heated O2 Sensor (H2OS) to detect if
the deterioration of the sensor has exceeded thresholds. An additional
HO2S is located downstream of the Warm-Up Three Way Catalytic Converter
(WU-TWC) to determine the efficiency of the catalyst.
Although the downstream
H2OS is similar to the type used for fuel control, it functions
differently. The downstream HO2S is monitored to determine if a voltage is
generated. That voltage is compared to a calibrated acceptable
range.
The EVAP. monitoring is
a self-test strategy within the ECM that tests the integrity of the EVAP.
system. The complete evaporative system detects a leak or leaks that
cumulatively are greater than or equal to a leak caused by a 0.040 inch
and 0.020 inch diameter orifice.
The A/C system
monitoring is a self-test strategy within the ECM that monitors
malfunction of all A/C system component at A/C ON.
The comprehensive
components monitoring is a self-test strategy within the ECM that detects
fault of any electronic powertrain components or system that provides
input to the ECM and is not exclusively an input to any other OBD-II
monitor. |