Home
›
Heating,Ventilation, Air Condioning
›
Air conditioning System
›
Ambient sensor
Air conditioning System › Ambient sensor: Repair procedures
INSPECTION
1.
Ignition "OFF"
2.
Disconnect ambient temperature sensor.
3.
Check the resistance of ambient temperature sensor between terminals 1 and 2 whether it is changed by changing of the ambient temperature.
[Specification]
Temperature(°C)
Resistance(kΩ ± 3%)
-20
290.17
-10
165.79
0
97.83
10
59.67
20
37.47
30
24.17
40
15.99
50
10.82
4.
If the measured resistance is not specification, substitute with a known-good ambient temperature sensor and check for proper operation.
5.
If the problem is corrected, replace the ambient temperature sensor.