Home › Heating,Ventilation, Air Condioning › Controller › Manual Controller

Controller › Manual Controller: Repair procedures

REPLACEMENT
1.
Disconnect the negative (-) battery terminal.
2.
After disconnect the mounting clip, remove the conter facia panel(A).

3.
After loosening the mounting screw, remove the center facia lower panel(A).

4.
Remove the heater & A/C controller (A) after loosening 4 screws.

5.
Disconnect the connectors (A) from the center facia.

6.
Installation is the reverse order of removal.
SELFDIAGNOSIS
1.
Self-diagnosis process
The F.A.T.C. module self test feature will detect electrical malfunction and provide error codes for system components with suspected failures.

DTC data can be retrieved from the control panel directly or from the DLC using the Hi-Scan Pro.
2.
How to read self-diagnostic code
After the display panel flickers three times every 0.5 second, the corresponding fault code flickers on the setup temperature display panel every 0.5 second and will show two figures. Codes are displayed in numerical format
Fault code
Fault code
Fail description
Control unit
0
Normal
11
In-car temperature sensor open (High)
12
In-car temperature sensor short (Low)
13
Ambient temperature sensor open (High)
14
Ambient temperature sensor short (Low)
15
Water temperature sensor open (High)
16
Water temperature sensor short (Low)
17
Evaporator temperature sensor open (High)
18
Evaporator temperature sensor short (Low)
19
Air mix potentiometer open (Low) - Driver
19
Air mix potentiometer short (High) - Driver
20
Air mix motor (Driver)
21
Direction potentiometer open (Low) - Driver
21
Direction potentiometer short (High) - Driver
22
Direction control motor (Driver)
23
Humidity sensor open (High)
24
Humidity sensor short (Low)

3.
Fault code display
(1)
Continuance operation : DTC code is one.

(2)
Continuance operation : DTC code is more two.

(3)
STEP operation
A. Nomal or one fault code is same as a continuance operation.
B. DTC code os more two.

4.
If fault codes are displayed during the check, Inspect malfunction causes by referring to fault codes.
5.
Fail safe
(1)
In-car temperature sensor: Control with the value of 25°C (77°F)
(2)
Ambient temperature sensor: Control with the value of 20°C (67°F)
(3)
Evaporator temperature sensor: Control with the value of -2°C (28.4°F)
(4)
Humidity sensor: Control with the value of 10%
(5)
Photo sensor: Control with the value of 0w/m²
(6)
Temperature control actuator (Air mix potentiometer):
A.
If temperature set 17°C-24.5°C, fix at maximum cooling position.
B.
If temperature set 25°C-32°C, fix at maximum heating position.
(7)
Mode control actuator (Direction potentiometer):
A.
Fix vent position, while selecting vent mode.
B.
Fix defrost position, while selecting all except vent mode.
(8)
A.Q.S sensor: AQS operation OFF.
Intake position : the position before selecting AQS switch.
(9)
Water temperature sensor : Control with the value of -2°C (28.4°F)
(10)
Intake control actuator
A.
Fix FRE position. while selecting FRE mode.
B.