AQS(Air Quality System)
keeps air inside in the most suitable state for driver. In polluted area
AQS detects hazardous gas and intercepts inflow automatically, Inversely,
In freshsh area it allows the inflow of air to prevent the shortage of air
and the accumulation of carbon dioxide. AQS sensor is located at front
side of condensor and once hazardous gas is detected, it delivers the
voltage signal to A/C controller for closing intake door.
The A/C controller sets
DTC B1257 if there is an open circuit in AQS sensor signal harness or the
measured voltage value of sensor is more than threshold
value.
Item
|
Detecting
Condition
|
Possible cause
|
DTC
Strategy
|
|
| •
|
Open Circuit in power
harness |
| •
|
Open circuit in ground
harness |
| •
|
Poor connection of connected
part | |
Threshold
value
|
|
Detecting
time
|
|
FAIL
SAFE
|
| •
|
Intake door : return to previous
state | |
| 1. |
Connect scantool to Data Link
Connector(DLC). |
| 3. |
Monitor the " AQS sensor " Parameter on the
Scantool. While making hazardous gas such as tobacco fumes around
the AQS sensor.

|
| 4. |
Are the DTC B1257 present and is parameter of
"AQS SENSOR" fixed?

Go to "Inspection" procedure.

Fault is intermittent caused by poor contact
in the sensor's and/or A/C controller's connector or was repaired
and A/C controller memory was not cleared. Thoroughly check
connectors for looseness, poor connection, bending, corrosion,
contamination, deterioration, or damage. Repair or replace as
necessary and then go to "Verification of Vehicle Repair"
procedure. |
| TERMINAL AND CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals.
Faults can also be caused by interference from
other electrical systems, and mechanical or chemical
damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

Repair as necessary and go to "Verification of
Vehicle Repair" procedure.

Go to "Signal circuit inspection"
procedure. |
| SIGNAL CIRCUIT
INSPECTION |
| 1. |
Check for open in harness.
| (2) |
Disconnect AQS
sensor. |
| (3) |
Measure resistance between terminal "4"
of AQS sensor and terminal "2" of A/C Control
Unit.
Specification : Approx. 0
Ω
|

|
| (4) |
Is the measured resistance within
specifications?

Go to "Ground circuit Inspection "
procedure.

Check for open in harness. Repair as
necessary and go to "Verification of Vehicle Repair"
procedure. | |
| GROUND CIRCUIT
INSPECTION |
| 1. |
Check for open in ground harness.
| (2) |
Disconnect AQS
sensor. |
| (3) |
Measure resistance between terminal "5"
of AQS sensor and chassis ground.
Specification : Approx. 0
Ω
|

|
| (4) |
Is the measured resistance within
specifications?

Go to "Component Inspection "
procedure.

Check for open in ground harness. Repair
as necessary and go to "Verification of Vehicle Repair"
procedure. | |
| 1. |
Check AQS sensor.
| (3) |
Measure voltage between terminal "4" and
"5" of AQS sensor.
Specification : Refer to the
specifications.
|

Operating
condition
|
Voltage
|
Note
|
Right after IGN "ON"
|
2.5V ± 0.3V
|
preheating(35 ± 2sec)
|
Normal
|
4.3V ± 0.3V
|
Intake door : Fresh
|
Gas detected
|
0.9V ± 0.3V
|
Intake door :
Recirculation
|
Specifications : Voltage value of AQS
sensor as a function of position of operating
condition. |
| (4) |
Is the measured voltage within
specifications?

Check connectors for looseness, poor
connection, bending, corrosion, contamination, deterioration,
or damage. Repair or replace as necessary and then go to
"Verification of Vehicle Repair" procedure.

Substitute with AQS sensor and check for
proper operation.
If the problem is corrected, replace AQS
sensor and then go to "Verification of Vehicle Repair"
procedure. | |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and select "Diagnostic
Trouble Codes(DTCs)" mode and then clear
DTC. |
| 2. |
Operate the vehicle and monitor the DTC on the
scantool. |
| 3. |
Are any DTCs present?

Go to the applicable troubleshooting
procedure.

System is performing to specification at this
time. |
※ Voltage value of AQS
sensor as a function of position of operating condition.
Operating
condition
|
Voltage
|
Note
|
Right after
IGN "ON"
|
2.5V ±
0.3V
|
preheating(35 ± 2sec)
|
Normal
|
4.3V ±
0.3V
|
Intake door
: Fresh
|
Gas
detected
|
0.9V ±
0.3V
|
Intake door
: Recirculation
|