Home › Heating,Ventilation, Air Condioning › Troubleshooting

B1259

COMPONENT LOCATION

GENERAL DESCRIPTION
AQS(Air Quality System) keeps air inside in the most suitable state for driver. In polluted area AQS detects hazardous gas and intercepts inflow automatically, Inversely, In freshsh area it allows the inflow of air to prevent the shortage of air and the accumulation of carbon dioxide. AQS sensor is located at front side of condensor and once hazardous gas is detected, it delivers the voltage signal to A/C controller for closing intake door.
DTC DESCRIPTION
The A/C controller sets DTC B1259 if preheating time of AQS sensor is over 40sec or signal from AQS sensor is not within specifications.
DTC DETECTING CONDITION
Item
Detecting Condition
Possible cause
DTC Strategy
•
Voltage/time check
•
Faulty AQS Sensor
•
Poor connection of connected part
Threshold value
•
Voltage :
Preheating - 2.5V±0.3V
Normal - 4.3V±0.3V
Gas detected - 0.9V±0.3V
•
Preheating time > 40sec
Detecting time
-
FAIL SAFE
•
AQS function OFF
•
Intake door : return to previous state

MONITOR SCANTOOL DATA
1.
Connect scantool to Data Link Connector(DLC).
2.
Engine "ON"
3.
Monitor the " AQS sensor " Parameter on the Scantool. While making hazardous gas such as tobacco fumes around the AQS sensor.

4.
Are the DTC B1259 present and is parameter of "AQS SENSOR" fixed?

Go to "Inspection" procedure.

Fault is intermittent caused by poor contact in the sensor's and/or A/C controller's connector or was repaired and A/C controller memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.
TERMINAL AND CONNECTOR INSPECTION
1.
Many malfunctions in the electrical system are caused by poor harness and terminals.
Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2.
Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3.
Has a problem been found?

Repair as necessary and go to "Verification of Vehicle Repair" procedure.

Go to "Signal circuit inspection" procedure.
SIGNAL CIRCUIT INSPECTION
1.
Check for open in harness.
(1)
Ignition "ON"
(2)
Disconnect AQS sensor.
(3)
Measure voltage value between terminal "6" of AQS sensor and chassis ground.

Specification : Approx. 12V

(4)
Is the measured resistance within specifications?

Go to "Component inspection " procedure.

Check for open in harness. Repair as necessary and go to "Verification of Vehicle Repair" procedure.
COMPONENT INSPECTION
1.
Check AQS sensor.
(1)
Engine "ON"
(2)
Connect AQS sensor.
(3)
Measure voltage between terminal "4" and "5" of AQS sensor.

Specification : Refer the specifications.

Operating condition
Voltage
Note
Right after IGN "ON"
2.5V ± 0.3V
preheating(35 ± 2sec)
Normal
4.3V ± 0.3V
Intake door : Fresh
Gas detected
0.9V ± 0.3V
Intake door : Recirculation

Specifications : Voltage value of AQS sensor as a function of position of operating condition.
(4)
Is the measured voltage within specifications?

Check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and then go to "Verification of Vehicle Repair" procedure.

Substitute with a AQS sensor and check for proper operation.
If the problem is corrected, replace AQS sensor and then go to "Verification of Vehicle Repair" procedure.
VERIFICATION OF VEHICLE REPAIR
After a repair, it is essential to verify that the fault has been corrected.
1.
Connect scantool and select "Diagnostic Trouble Codes(DTCs)" mode and then clear DTC.
2.
Operate the vehicle and monitor the DTC on the scantool.
3.
Are any DTCs present?

Go to the applicable troubleshooting procedure.

System is performing to specification at this time.
SPECIFICATION
※ Voltage value of AQS sensor as a function of position of operating condition.
Operating condition
Voltage
Note
Right after IGN "ON"
2.5V ± 0.3V
preheating(35 ± 2sec)
Normal
4.3V ± 0.3V
Intake door : Fresh
Gas detected
0.9V ± 0.3V
Intake door : Recirculation