A water temp. sensor
located at heater unit, detects coolant temperature. Its signal is used
for cold engine lockout control. When the driver operates the heater
before the engine is warmed up, the signal from sensor causes the heater
control unit to reduce blower motor speed until coolant temperature
reaches the threshold value.
The A/C controller sets
DTC B1203 if there is a short circuit in water temp. sensor signal harness
or the measured resistance value of sensor is less than threshold
value(about 1.2kΩ)
Item
|
Detecting
Condition
|
Possible cause
|
DTC
Strategy
|
|
| •
|
Short circuit in
harness |
| •
|
Faulty water temp.
Sensor |
| •
|
Faulty A/C control
unit | |
Threshold
value
|
|
Detecting
time
|
|
FAIL
SAFE
|
| •
|
Control with the value of
-2°C(28.4°F) | |
| 1. |
Connect scantool to data link
connector(DLC). |
| 3. |
Monitor the "WATER TEMP. SENSOR" Parameter on
the Scantool.

|
| 4. |
Are the DTC B1203 present and is parameter of
"WATER TEMP. SENSOR" fixed?
※ Parameter of "WATER TEMP. SENSOR" will be
fixed at -2°C(28.4°F), if there is any fault in WATER TEMP.
SENSOR.

Go to "Inspection" procedure.

Fault is intermittent caused by poor contact
in the sensor's and/or A/C controller's connector or was repaired
and A/C controller memory was not cleared. Thoroughly check
connectors for looseness, poor connection, bending, corrosion,
contamination, deterioration, or damage. Repair or replace as
necessary and then go to "Verification of Vehicle Repair"
procedure. |
| TERMINAL AND CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness and terminals.
Faults can also be caused by interference from
other electrical systems, and mechanical or chemical
damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

Repair as necessary and go to "Verification of
Vehicle Repair" procedure.

Go to "Signal circuit inspection"
procedure. |
| SIGNAL CIRCUIT
INSPECTION |
| 1. |
Check for short to ground in
harness.
| (2) |
Disconnect water temp.
sensor. |
| (3) |
Measure resistance between terminal "1"
of water temp. sensor and chassis ground.
Specification : Approx.
∞Ω
|

|
| (4) |
Is the measured resistance within
specifications?

Go to "Component Inspection"
procedure.

Check for short to ground in harness.
Repair as necessary and go to "Verification of Vehicle Repair"
procedure. | |
| 1. |
Check water temp. sensor.
| (2) |
Disconnect water temp.
sensor. |
| (3) |
Measure resistance between terminal "1"
and "2" of water temp. sensor.
Specification : Refer the
specifications in fig 3.
|

|
| (4) |
Is the measured resistance within
specifications in fig 3)? (tolerance limits ± 3%)

Go to "Check A/C Control Unit"
procedure.

Substitute with a known-good water temp.
sensor and check for proper operation.
If the problem is corrected, replace
water temp. sensor and then go to "Verification of Vehicle
Repair"
procedure. | |
| 2. |
Check A/C Control Unit
| (2) |
Disconnect water temp.
sensor. |
| (3) |
Measure Voltage between terminal "7" of
A/C Control Unit and chassis ground.
Specification : Approx.
5V
|

|
| (4) |
Is the measured voltage within
specifications?

Check connectors for looseness, poor
connection, bending, corrosion, contamination, deterioration,
or damage. Repair or replace as necessary and then go to
"Verification of Vehicle Repair" procedure.

Substitute with a known-good A/C Control
Unit and check for proper operation.
If the problem is corrected, replace A/C
Control Unit and then go to "Verification of Vehicle Repair"
procedure. | |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and select "Diagnostic
Trouble Codes(DTCs)" mode and then clear
DTC. |
| 2. |
Operate the vehicle and monitor the DTC on the
scantool. |
| 3. |
Are any DTCs present?

Go to the applicable troubleshooting
procedure.

System is performing to specification at this
time. |
Temperature[°C(°F)]
|
Resistance(kΩ)
|
Temperature[°C(°F)]
|
Resistance(kΩ)
|
-20(-4)
|
97.75
|
20(68)
|
12.51
|
-10(14)
|
55.85
|
30(86)
|
8.05
|
0(32)
|
32.91
|
40(104)
|
5.31
|
10(50)
|
19.99
|
50(122)
|
3.95
|