DOOR LOCK
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.5
and No.14 terminals when power and ground are connected to the No.11
and No.13 in the ICM-B. |
| 2. |
There should be no continuity between the No.5
and No.14 terminals when power is
disconnected. |
DOOR UNLOCK
Check for continuity
between the terminals.
| 1. |
There should be no continuity between the No.4
and No.14 terminals when power and ground are connected to the No.10
and No.13 in the ICM-B. |
| 2. |
There should be continuity between the No.4
and No.14 terminals when power is
disconnected. |
BURGLAR ALARM HORN
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.8
and No.18 terminals when power and ground are connected to the No.6
and No.19 in the ICM-B. |
| 2. |
There should be no continuity between the No.8
and No.18 terminals when power is
disconnected. |
BURGLAR ALARM
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.3
and No.10 terminals when power and ground are connected to the No.1
and No.11 terminals in the ICM-A. |
| 2. |
There should be no continuity between the No.3
and No.10 terminals when power is
disconnected. |
HAZARD LAMP
Check for continuity
between the terminals.
| 1. |
There should be continuity between the No.3
and No.12 terminals when power and ground are connected to the No.3
and No.17 terminals in the ICM-B. |
| 2. |
There should be no continuity between the No.3
and No.12 terminals when power is
disconnected. |