The normal operating
temperature of the HO2S(Heated Oxygen Sensor) ranges from 350 to 850°C(662
to 1562°F). The HO2S heater greatly decreases the amount of time required
for fuel control to become active. The ECM provides a pulse width
modulated control circuit to adjust current through the heater. When the
HO2S is cold, the value of the resistance is low and the current in the
circuit is high. On the contrary, if the temperature in the resistor of
the sensor rises, the current drops gradually.
The ECM determines if a
front HO2S heater fault has occurred and sets DTC P0030 if the front HO2S
heater control driver inside the ECM fails, if HO2S is not operational
(after an elapse of predetermined time) since engine start, or when the
front HO2S tip temperature is out of normal working range.
Item
|
Detecting
Condition
|
Possible Cause
|
DTC Strategy
|
case
1
|
| •
|
Evaluate O2 sensor element temperature
via measuring element
resistance | |
| •
|
Related fuse blown or
missing |
| •
|
Heater control circuit open or
short |
| •
|
Power supply circuit open or
short |
| •
|
Poor connection or damaged
harness |
|
case
2
|
| •
|
Check operative readiness after certain
time with active
heating | |
case
3
|
| •
|
Check if the controller gain/offset are
within min/max limit | |
Enable Conditions
|
| •
|
11 ≤ Battery voltage ≤
16V |
| •
|
Heater power control active since a
certain time (O2 Sensor element temperature check) > 20
sec. |
| •
|
Heater control activating(controller
malfunction check and element resistance
check) | |
Threshold Value
|
case
1
|
| •
|
690°C (1, 274°F) < Front HO2S element
temperature < 875°C (1,
607°F) | |
case
2
|
| •
|
Heating time > 30~100
sec. | |
case
3
|
| •
|
Values out of boundaries and timer >
THD | |
Diagnostic Time
|
case
1
|
|
case
2
|
|
case
3
|
|
Mil On Condition
|
|

| 1. |
Connect scan tool and select "Diagnostic
Trouble Codes(DTCs)" mode. |
| 2. |
Press F4(DTAL) to select DTC information from
the DTCs menu. |
| 3. |
Confirm that "DTC Readiness Flag" indicates
"Complete". If not, drive the vehicle within conditions noted in the
freeze frame data or enable
conditions. |
| 4. |
Read "DTC Status"
parameter. |
| 5. |
Is parameter displayed "History(Not Present)
fault"?
| -
|
History (Not Present) fault : DTC
occurred but has been
cleared. |
| -
|
Present fault : DTC is occurring
at present
time. | |

▶ Fault is intermittent caused by poor contact
in the sensor's and/or ECM's connector or was repaired and ECM
memory was not cleared. Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. Repair or replace as necessary and then go to
"Verification of Vehicle Repair" procedure.

▶ Go to next step as
below. |
| 2. |
Disconnect HO2S
connector. |
| 3. |
Ignition "ON" & Engine
"OFF" |
| 4. |
Measure voltage between terminal 5 of the HO2S
heater harness connector and chassis ground.

|
| 5. |
Is voltage within the
specification?

▶ Go to "Control Circuit Inspection"
procedure

▶ Check for an open in the power supply
circuit between the main relay and the HO2S.
▶ Especially check for "SENSOR2 FUSE 15A" is
installed and not blown.
▶ Repair or replace as necessary and go to
"Verification of Vehicle Repair" procedure.
|
HO2S must have a clean air reference to
function properly. The air is obtained by way of the sensor
wire(s). Do not attempt to repair the wire(s), connector, or
the
terminals. | |
| CONTROL CIRCUIT
INSPECTION |
| 1. |
Measure voltage between terminal 6 of the HO2S
heater harness connector and chassis ground
Specification : Approx.
4~5V
|

|
| 2. |
Is voltage within the
specification?

▶ Go to "Component Inspection"
procedure

▶ Repair or replace as necessary and go to
"Verification of Vehicle Repair" procedure
|
HO2S must have a clean air reference to
function properly. The air is obtained by way of the sensor
wire(s). Do not attempt to repair the wire(s), connector, or
the
terminals. | |
| TERMINAL AND CONNECTOR
INSPECTION |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness(es) and terminals. Faults can also be caused
by interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and go to "Verification
of Vehicle Repair" procedure.

▶ Go to next step as
below. |
| 2. |
Measure resistance between terminals 5 and 6
of the sensor connector (Component side).
Specification
HO2S Heater
|
Normal
Parameter
|
18 ~
20°C
|
Heater
Resistance
|
2.4~2.9Ω
|

|
| 3. |
Is resistance within the
specification?

▶ Check for poor connection between ECM and
component: backed out terminal, improper mating, broken locks or
poor terminal to wire connection. Repair as necessary and go to
"Verification of Vehicle Repair" procedure.

▶ Check HO2S for contamination, deterioration,
or damage. Substitute with a known-good HO2S and check for proper
operation. If the problem is corrected, replace HO2S and then go to
"Verification of Vehicle Repair"
procedure. |
| VERIFICATION OF VEHICLE
REPAIR |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scan tool and select "Diagnostic
Trouble Codes(DTCs)" mode. |
| 2. |
Press F4(DTAL) and confirm that "DTC Readiness
Flag" indicates "Complete". If not, drive the vehicle within
conditions noted in the freeze frame data or enable
conditions. |
| 3. |
Read "DTC Status"
parameter. |
| 4. |
Is parameter displayed "History(Not Present)
fault"?

▶ System performing to specification at this
time. Clear the DTC

▶ Go to the applicable troubleshooting
procedure. |

HO2S Heater
|
Normal
Parameter
|
18 ~
20°C
|
Heater
Resistance
|
2.4~2.9Ω
|