Home › Brake System › Troubleshooting

C2402 Motor electrical

COMPONENT LOCATION

General Description
The HECU supplies battery power to the electric motor with a motor relay which is controlled by the Electronic Control Unit(ECU). The electric motor pump supplies hydraulic pressure to all wheel brake calipers by operating the piston inside the pump.
DTC Description
The ABS ECU monitors the pump motor relay or fuse open, open or short in motor or motor lock and then sets this code if a malfunction is detected.
DTC Detecting Condition
Item
Detecting Condition
Possible cause
DTC
Strategy
•
Voltage Monitoring
•
Open or short of power supply circuit (ESC2)
•
Faulty HECU
Case1
(Motor Relay continous off,Open,Fuse blown)
Detect
Mode
•
Continuous (If the pump is switched on (FET on))
Enable
Conditions
•
If the motor relay is switched ON and motor voltage < (IGN voltage – 4.0V) continued for 100msec, the failure is detected.
Fail Safe
•
Pressure decrease is no longer possible. (wheels block)
•
The ABS/ESC functions are inhibited and the EBD function is reduced.
•
The ABS/EBD/ESC warning lamps are activated.
Case2
(Motor Lock)
Detect
Mode
•
Continuous (If the pump is in the transition "on → off")
Enable
Conditions
•
After the end of the actuation of the motor relay, the pump motor is still in motion and is generating a voltage during it's slowdown. The generated mortor voltage is monitored for a certain time on high level. The time depends on the supply voltage and is in the range of 300ms to 125ms. If the slow down condition isn't met, the pump is activated again and the slowdown time is measured again. This is repeated for maximum 3times. If, after the last pump activation, the pump motor slowdown time is still to short, a failure is detected.
1st actuation : 200ms
2st actuation : 1000ms
3st actuation : 3000ms
Fail Safe
•
Pressure decrease is no longer possible. (wheels block)
•
The ABS/ESC functions are inhibited and the EBD function is reduced.
•
The ABS/EBD/ESC warning lamps are activated.
Case3
(Grond loss,Motor relay continous on, Motor Short to BATT)
Detect
Mode
•
Continuous (If the pump is switched off i.e. not actuation and no slowdown)
Enable
Conditions
•
Motor relay is switched OFF, VMR > 2.0V continued for 1sec, the failure is detected.
Fail Safe
•
The return pump does not work correct.
•
The ABS/ESC functions are inhibited and the EBD function is reduced.
•
The ABS/EBD/ESC warning lamps are activated.

Monitor Actuation Test
1.
Connect scantool to Data Link Connector(DLC)
2.
Ignition "ON" & Engine "OFF".
3.
Select the "Actuation Test" mode on the scantool.
4.
Inspect operating status of inlet valve with Actuation Test.

Specification : It's normal if operating sound is heard.

5.
Does a inlet valve operate normally?

▶ Fault is intermittent caused by poor connection in motor circuit or was repaired and HECU memory was not cleared. Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage. Repair or replace as necessary and then go to "Verification Of Vehicle Repair" procedure.

▶ Go to "W/Harness Inspection" procedure.
Terminal & Connector Inspection
1.
Many malfunctions in the electrical system are caused by poor harness(es) and terminals. Faults can also be caused by interference from other electrical systems, and mechanical or chemical damage.
2.
Thoroughly check connectors for looseness, poor connection, bending, corrosion, contamination, deterioration, or damage.
3.
Has a problem been found?

▶ Repair as necessary and then go to "Verification Of Vehicle Repair" procedure.

▶ Go to "Power Circuit Inspection" procedure.
Power Supply Circuit Inspection
1.
Ignition "OFF".
2.
Disconnect HECU connector.
3.
Ignition "ON".
4.
Measure voltage between terminal "2" of the HECU harness connector and chassis ground.

Specification : Approx. B+

5.
Is the measured voltage within specifications?

▶ Go to "Ground Circuit Inspection" procedure.

▶ Check for damaged harness and open or short to GND between the battery terminal(+) and terminal "2" of the HECU harness connector. Check for open or blown 40A ABS fuse referring to "Circuit Diagram". Repair as necessary and then go to "Verification Of vehicle Repair" procedure.
Ground Circuit Inspection
1.
Ignition "OFF".
2.
Disconnect HECU connector.
3.
Measure resistance between terminal "1" of the HECU harness connector and chassis ground.

Specification : Approx. below 1 Ω

4.
Is the measured resistance within specifications?

▶ Substitute with a known-good HECU and check for proper operation. If problem is corrected, replace HECU and then go to "Verification Of Vehicle Repair" procedure.

▶ Check for damaged harness and poor connection between terminal "1" of the HECU harness connector and chassis ground. Repair as necessary and then go to "Verification Of vehicle Repair" procedure.
Verification of Vehicle Repair
After a repair, it is essential to verify that the fault has been corrected.
1.
Connect scantool and select "Diagnostic Trouble Codes (DTCs)" mode
2.
Using a scantool, Clear DTC.
3.
Operate the vehicle within DTC Detecting Condition in General Information. (Start and drive vehicle in gear and maintain vehicle speed at or above 30kmh(18.6mph).
4.
Are any DTCs present?

▶ Go to the applicable troubleshooting procedure.

▶ System performing to specification at this time.