The HECU supplies
battery power to the electric motor with a motor relay which is controlled
by the Electronic Control Unit(ECU). The electric motor pump supplies
hydraulic pressure to all wheel brake calipers by operating the piston
inside the pump.
The ABS ECU monitors the
pump motor relay or fuse open, open or short in motor or motor lock and
then sets this code if a malfunction is detected.
Item
|
Detecting
Condition
|
Possible
cause
|
DTC Strategy
|
|
| •
|
Open or short of power supply circuit
(ESC2) |
|
Case1 (Motor Relay continous
off,Open,Fuse blown)
|
Detect Mode
|
| •
|
Continuous (If the pump is switched on
(FET on)) | |
Enable Conditions
|
| •
|
If the motor relay is switched ON and
motor voltage < (IGN voltage – 4.0V) continued for 100msec,
the failure is
detected. | |
Fail
Safe
|
| •
|
Pressure decrease is no longer possible.
(wheels block) |
| •
|
The ABS/ESC functions are inhibited and
the EBD function is reduced. |
| •
|
The ABS/EBD/ESC warning lamps are
activated. | |
Case2 (Motor
Lock)
|
Detect Mode
|
| •
|
Continuous (If the pump is in the
transition "on → off") | |
Enable Conditions
|
| •
|
After the end of the actuation of the
motor relay, the pump motor is still in motion and is
generating a voltage during it's slowdown. The generated
mortor voltage is monitored for a certain time on high level.
The time depends on the supply voltage and is in the range of
300ms to 125ms. If the slow down condition isn't met, the pump
is activated again and the slowdown time is measured again.
This is repeated for maximum 3times. If, after the last pump
activation, the pump motor slowdown time is still to short, a
failure is detected.
1st actuation : 200ms
2st actuation : 1000ms
3st actuation :
3000ms | |
Fail
Safe
|
| •
|
Pressure decrease is no longer possible.
(wheels block) |
| •
|
The ABS/ESC functions are inhibited and
the EBD function is reduced. |
| •
|
The ABS/EBD/ESC warning lamps are
activated. | |
Case3 (Grond loss,Motor relay
continous on, Motor Short to BATT)
|
Detect Mode
|
| •
|
Continuous (If the pump is switched off
i.e. not actuation and no
slowdown) | |
Enable Conditions
|
| •
|
Motor relay is switched OFF, VMR >
2.0V continued for 1sec, the failure is
detected. | |
Fail
Safe
|
| •
|
The return pump does not work
correct. |
| •
|
The ABS/ESC functions are inhibited and
the EBD function is reduced. |
| •
|
The ABS/EBD/ESC warning lamps are
activated. | |
| 1. |
Connect scantool to Data Link
Connector(DLC) |
| 2. |
Ignition "ON" & Engine
"OFF". |
| 3. |
Select the "Actuation Test" mode on the
scantool. |
| 4. |
Inspect operating status of inlet valve with
Actuation Test.
Specification : It's normal if operating
sound is heard.
|

|
| 5. |
Does a inlet valve operate
normally?

▶ Fault is intermittent caused by poor
connection in motor circuit or was repaired and HECU memory was not
cleared. Thoroughly check connectors for looseness, poor connection,
bending, corrosion, contamination, deterioration, or damage. Repair
or replace as necessary and then go to "Verification Of Vehicle
Repair" procedure.

▶ Go to "W/Harness Inspection"
procedure. |
| Terminal & Connector
Inspection |
| 1. |
Many malfunctions in the electrical system are
caused by poor harness(es) and terminals. Faults can also be caused
by interference from other electrical systems, and mechanical or
chemical damage. |
| 2. |
Thoroughly check connectors for looseness,
poor connection, bending, corrosion, contamination, deterioration,
or damage. |
| 3. |
Has a problem been found?

▶ Repair as necessary and then go to
"Verification Of Vehicle Repair" procedure.

▶ Go to "Power Circuit Inspection"
procedure. |
| Power Supply Circuit
Inspection |
| 2. |
Disconnect HECU
connector. |
| 4. |
Measure voltage between terminal "2" of the
HECU harness connector and chassis ground.
Specification : Approx.
B+
|

|
| 5. |
Is the measured voltage within
specifications?

▶ Go to "Ground Circuit Inspection"
procedure.

▶ Check for damaged harness and open or short
to GND between the battery terminal(+) and terminal "2" of the HECU
harness connector. Check for open or blown 40A ABS fuse referring to
"Circuit Diagram". Repair as necessary and then go to "Verification
Of vehicle Repair" procedure. |
| Ground Circuit
Inspection |
| 2. |
Disconnect HECU
connector. |
| 3. |
Measure resistance between terminal "1" of the
HECU harness connector and chassis ground.
Specification : Approx. below 1
Ω
|

|
| 4. |
Is the measured resistance within
specifications?

▶ Substitute with a known-good HECU and check
for proper operation. If problem is corrected, replace HECU and then
go to "Verification Of Vehicle Repair" procedure.

▶ Check for damaged harness and poor
connection between terminal "1" of the HECU harness connector and
chassis ground. Repair as necessary and then go to "Verification Of
vehicle Repair" procedure. |
| Verification of Vehicle
Repair |
After a repair, it is
essential to verify that the fault has been corrected.
| 1. |
Connect scantool and select "Diagnostic
Trouble Codes (DTCs)" mode |
| 2. |
Using a scantool, Clear
DTC. |
| 3. |
Operate the vehicle within DTC Detecting
Condition in General Information. (Start and drive vehicle in gear
and maintain vehicle speed at or above
30kmh(18.6mph). |
| 4. |
Are any DTCs present?

▶ Go to the applicable troubleshooting
procedure.

▶ System performing to specification at this